8 - DIP SWITCH DIP1
The settings are stored during the rest phase (gate closed).
The default settings are highlighted in the boxes with grey background.
DIP
Function
PHOTOCELL
DIP1_1
DURING
OPENING
OPERATING
DIP 2
1_
LOGIC
DIP 3
1_
HAMMER STROKE
Description
Status
When the photocell is intercepted during both opening and closing, the gate
motion is locked until the photocell is freed.
ON
Subsequently, there is always an opening phase.
During pause, the photocell reloads the pause time.
The photocell stops and immediately inverts the gate motion during closing
while it is uninfluential during opening.
OFF
During pause, the photocell reloads the pause time.
AUTOMATIC logic
Operation in response to the START command:
• Gate closed
ON
• During opening
• Gate open
• During closing
STEP-BY-STEP WITH STOP logic
Operation in response to the START command:
• Gate closed
• During opening
OFF
• Gate open (PAUSE)
• During closing
• After a STOP
Operation: following a START, OPENING or PEDESTRIAN command, the
following will occur in sequence:
• electric lock activation
• closing pulse of 1 second
• opening
ON
• after 2 seconds, electric lock deactivation
This function cannot be activated with a sliding gate configuration and is
unadvisable with electromechanical operators.
Hammer stroke disabled.
OFF
Simultaneous electric lock activation and opening.
OPENS
→
UNINFLUENTIAL
→
Reloads the automatic closing time if automatic
→
closing is enabled, otherwise it closes.
OPENS
→
OPENS
→
STOPS
→
STOPS
→
OPENS
→
inverts the motion
→
F4 PLUS