INSTALLATION:
ALWAYS TURN OFF THE POWER SUPPLY FROM MAIN CIRCUIT BREAKER FIRST!
1. DISCONNECT POWER TO LUMINAIRE DISCONNECT POWER TO
LUMINAIRE OR CIRCUIT (IF POSSIBLE). ENSURE ALL POWER IS
OFF BY USING A VOLTMETER OR OTHER APPROVED METHOD TO
CONFIRM.
2. REMOVE EXISTING TUBE LAMP(S).
3. REMOVE TROFFER LENS, IF PRESENT.
4. REMOVE EXISTING FLUORESCENT TUBE BY ROTATING ONE-QUARTER TURN AND SLIDING LAMP(S).
2
5. REMOVE BALLAST COVER (COVER MAY BE SECURED WITH SCREWS OR TABS).
6. ENSURE BOTH THE ENDS OF THE LED TUBE ARE ALIGNED WITH SOCKET, THEN INSERT LED LAMP IN THE
CORRECT WAY BY SLIDING PINS INTO SOCKETS AND ROTATING A QUARTER TURN UNTIL THE LED TUBE
LOCKS IN PLACE.
7. LED LAMPS ARE NOW FULLY INSTALLED.
8. REPLACE TROFFER LENS, IF PRESENT.
9. AFTER MODIFICATION COMPLETED. ATTACH THE REPLACEMENT MARKING AND CAUTIONARY LABEL TO A
VISIBLE PLACE ON THE LUMINAIRE AND KEEP IT VISIBLE AFTER INSTALLATION.
10. RESTORE POWER TO CIRCUIT/LUMINAIRE AND TEST LIGHT. IF NECESSARY, ADJUST POSITION OF LED TUBE
AND POWER ON.
EiKO Global | 23220 W 84th St, Shawnee, KS 66227 | (P) 1-800-852-2217
EiKO Canada | 81 King St, Barrie, Ontario L4N 6B5 | (P) 1-705-721-5189
3
1
4
OFF
FLUROSCENT TUBES
TO BE REPLACED
eiko.com