G
B
INFRARED SIGNAL RECEIVER - RX
SYSTEM CHECK
After finishing the mounting procedure, check the correct working by doing the following:
- Check on the infrared receiver RX VERTIGO that the red led is on. If it is not so, align
transmitter and receiver to turn the red led on.
- Place an object between them and check that the red LED turns OFF and that at the same
time on the control panel the corresponding LED EDGE is OFF and a while the object is present.
- Repeat the process on the other VERTIGO photocells installed.
- Then perform a system check of all the photocells installed by activating the movement of
the automation and checking that when an object is present the automation stops/reverses
when closing, or stops/continues to open when opening.
CLOSING THE VERTIGO CONTAINERS
Lastly, place the screw cover caps (6) (12) both on the TX and on the RX of the VERTIGO (Fig.
2-5), by inserting them into the 4 holes so that they are perfectly attached.
TROUBLESHOOTING
The green LED DLTX of the TX does not turns on as you give power supply.
The red LED DLRX of the RX does not turns on as you give power supply.
The gate does not open.
The gate does not close.
PROBLEM
TECHNICAL SPECIFICATIONS
VERTIGO RECEIVER
- POWER
- MAXIMUM ABSORPTION
- OPERATING TEMPERATURE
- COVER
- BASE
- BELLOW
- PROTECTION LEVEL
- WEIGHT
VERTIGO TRANSMITTER
- POWER
- POWER ABSORBED
- OPERATING TEMPERATURE
- COVER
- BASE
- BELLOW
- PROTECTION LEVEL
- WEIGHT
TX INFRARED SIGNAL TECHNICAL DETAILS
- RANGE
- WAVELENGTH
- DIMENSION OF THE DETECTION AREA
- Check that on transmitter terminals is present the power supply 12÷24 V ac/dc
- Check that on TX and RX terminals is present the power supply 12÷24 V ac/dc and the correct
allignment between them
VERTIGO is not aligned or stuck (red led on RX turned OFF). Check alignment between TX and RX
up to obtain red led turned on on RX.
AUTOTEST failed.
VERTIGO is not aligned or stuck (red led on RX turned OFF). Check alignment between TX and RX
up to obtain red led turned on on RX.
16
12÷24 V ac/dc
25 mA
-20°C ÷ +60°C
in polycarbonate
in ABS
in silicon
IP55
0,135 kg
12÷24 V ac/dc
20 mA
-20°C ÷ +60°C
in polycarbonate
in ABS
in silicon
IP55
0,130 kg
3 m
850 nm
diametre 20 mm
CHECK