Orbis PROXIMAT Guia De Inicio Rapido página 3

Interruptor de proximidad
Idiomas disponibles

Idiomas disponibles

PROXIMITY SWITCH
USAGE INSTRUCTIONS
PROTECTIVE
COVER
LENS
DESCRIPTION
The PROXIMAT proximity switch captures invisible infrared light from
people or other heat sources, but without emitting any type of radiation.
When a heat source moves in front of a PROXIMAT proximity switch, its
output circuit will be activated and once it no longer captures this movement
it will be deactivated after an adjustable time delay.
The PROXIMAT proximity switch will only react in this way when the
environmental light conditions are below a pre-established level.
INSTALLATION
WARNING: The assembly and installation of the electrical equipment must
only be carried out by an authorised installer.
THE POWER SUPPLY MUST BE SWITCHED OFF BEFORE
COMMENCING THE INSTALLATION.
The unit is internally protected by a safety circuit against interference.
However, very strong magnetic fields can modify its operation. It should not,
therefore, be installed close to inductive loads, such as motors,
transformers and telephony antennas etc.
MOUNTING
On a wall, taking care to avoid highly reflective surfaces, such as liquids
and marble etc, elements that are subject to sharp changes in temperature
(heating, air conditioning or any possible air currents) or light sources.
DO NOT
PROTECT
EXPOSE TO
FROM RAIN
SUNLIGHT
Includes fastening accessory for inner and outer corners.
The ideal mounting height is between two and three metres and the heat
source movement should be transversal to the PROXIMAT lens.
AREA OF GREATEST
SENSITIVITY
PROXIMAT
CONNECTION COVER
ADJUSTMENT
BUTTONS
DO NOT
DO NOT INSTALL
INSTALL
OVER HEAT
CLOSE TO
SOURCES
LAMPS
The PROXIMAT proximity switch installation should take into account that
detection is produced by the crossing of the detection beams, and
therefor, if the heat source to be detected is parallel to be beams, the
detection will be produced at a closer distance because it can come much
closer before being detected since it does not cross the beams.
GREATER SENSITIVITY
In the above figures, the arrows show the direction of the person or object
to be detected.
The environmental temperature of the premises where the PROXIMAT
proximity switch is installed can have a significant influence of the
detection sensitivity. The higher the temperature the poorer the sensitivity,
because the unit operates by detecting the movement of a heat source.
(in most cases this is 36ºC, the temperature of the human body), the
closer the environmental temperature is to 36ºC, the poorer is the
detection.
CONNECTION
The unit should be connected as shown below
N
L
L
N
PUTTING INTO OPERATION. ADJUSTMENTS
Read this carefully before putting the PROXIMAT proximity switch into
service.
When connecting for the first time, or after prolonged period of switch off,
the unit will enter the TEST mode.
In this mode, the unit will independently detect the adjusted light level and
always with ten seconds timing, which will facilitate detection field
adjustment.
After five minutes, the unit will automatically pass to AUTO mode and
allow the time and light level to be adjusted.
AUTO can be entered after the five minutes by quickly switching off and
on (less than two seconds).
Then slowly rotate to the right until the lighting is switched on.
The front of the PROXIMAT proximity switch contains the selectors: "
for delay time adjustment, " S " for detection sensitivity and "
for luminosity adjustment.
ADJUSTING THE DETECTION FIELD
The head can be rotated through 180º moving the detection zone as
shown in the figure:
The following steps are required for detection field adjustment:
- Turn selector "S" to the maximum position.
- Turn the selector "
" to the "
- Set selector"
" to minimum.
LESS SENSITIVITY