4.4 Properly position the main post, drill holes with the impact drill, remove the dust in the bolt hole with a vacuum cleaner, and hammer
the expansion bolt into the hole. The length of the expansion bolt protruding from the ground shall not exceed 50mm, and the nut shall
not be tightened.
4.5 Fix the auxiliary post by reference to the mounting method of main post, and check
that the difference between the diagonal distances of the two post bottom plates is not
more than 3mm.
4.6 Tighten the expansion bolts (reference torque: 203N.m), and meanwhile check that
the post is vertical with a spirit level. Place the gasket at the bottom of the post to level
the post if necessary. Check that the upper surface of the gantry is level with a spirit
level.
Attention:
If the tightening torque of expansion bolt cannot reach 203N.m, the strength of concrete shall be rechecked.