Federal Signal Global Serie G-SND Sounder Instalación Y Instrucciones De Mantenimiento página 15

Tabla de contenido
Idiomas disponibles

Idiomas disponibles

120 Vac operation (no remote switching of tones)
a.
Set the voltage selector switches to 120 and AC.
b.
Turn the tone selector switch to the desired tone.
c.
Connect the line (hot) power source wire to the terminal block
position marked L1 on the PCB.
d.
Connect the neutral (common) power source wire to the terminal
block position marked L2 on the PCB.
e.
Connect ground wire to the terminal block position marked
EARTH.
24 Vdc operation (no remote switching of tones)
a.
Set the voltage selector switches to 230 and DC.
b.
Turn the tone selector switch to the desired tone.
c.
Connect the positive (+) power source wire to the terminal block
position marked L1 on the PCB.
d.
Connect the negative (–) power source wire to the terminal block
position marked L2 on the PCB.
e.
Connect ground wire to the terminal block position marked
EARTH.
220-240 Vac operation (remote switching of tones)
a.
Set the voltage selector switches to 230 and AC.
b.
Set the tone selector switch to 0.
c.
Connect the line (hot) power source wire to the terminal block
position marked L1 on the PCB.
d.
Connect the neutral (common) power source wire to the terminal
block position marked L2 on the PCB.
e.
Connect ground wire to the terminal block position marked
EARTH.
f.
Connect the common wire from the remote switching device to
the terminal block position marked SEL.
g.
Connect the tone select wires from the remote switching device
to the terminal block positions marked T1, T2, T3, and T4.
Model G-SND Global Series Sounder
Installation and Maintenance Instructions
15
Tabla de contenido
loading

Tabla de contenido