STEP 3
-Optional Direct Connect
Connect Water Lines
FOR RIGID TUBING:
1
Disconnect the bottom of the cold water plumbing line from the shut-off valve and gently bend the plumbing line for access to the
lower line fitting.
2
Screw the 3/8" Male OD daptor
3
Screw the 3/8" Female OD daptor
FOR FLEXIBLE TUBING:
1
Disconnect the bottom of the cold water plumbing line from the shut-off valve.
2
Screw the 3/8" Male OD daptor
3
Screw the 3/8" Female OD daptor
STEP 4
-Optional Direct Connect
Connect the 1/4" Plastic Tubing
ROM SYSTEM HE D INLET TO 3/8" FEM LE OD D PTOR:
1
Determine the length of 1/4" Plastic Tubing
daptor at the shut-off valve. Make sure to allow enough 1/4" Plastic Tubing to prevent kinking in the line.
2
Cut the 1/4" Plastic Tubing squarely on both ends.
3
Wet one end of the 1/4" Plastic Tubing with water and push it into the System Head Inlet until it stops.
NOTE: Do not bend or crimp 1/4" Plastic Tubing when inserting.
4
Wet the other end of the 1/4" Plastic Tubing with water and push it into the 3/8" Female OD daptor until it stops.
NOTE: Do not bend or crimp 1/4" Plastic Tubing when inserting.
FROM SYSTEM HE D OUTLET TO 3/8" M LE OD D PTOR:
5
Determine the length of 1/4" Plastic Tubing
on the lower end of the plumbing line. Make sure to allow enough 1/4" Plastic Tubing to prevent kinking in the line.
6
Cut the 1/4" Plastic Tubing squarely on both ends.
7
Wet one end of the 1/4" Plastic Tubing with water and push it into the System Head Outlet until it stops.
NOTE: Do not bend or crimp 1/4" Plastic Tubing when inserting.
Wet the other end of the 1/4" Plastic Tubing with water and push it into the 3/8" Male OD daptor until it stops.
NOTE: Do not bend or crimp 1/4" Plastic Tubing when inserting.
WFQT13000 & WFQT13500 Series
D
onto the compression fitting on the lower end of the plumbing line.
E
onto the cold water shut-off valve outlet port.
D
onto the existing nut on the lower end of the flexible hose.
E
onto the cold water shut-off valve outlet port.
F
that will be necessary to connect the System Head Inlet to the 3/8" Female OD
F
that will be necessary to connect the System Head Outlet to the 3/8" Male OD daptor
11
3
1
COLD W TER
V LVE
2
3
D
4
INLET
F
3
F
INLET
E
D
F
RIGID
TUBING
FLEX
E
TUBING
OUTLET
7
OUTLET
V4.0