WARNING: DISCONNECT POWER BEFORE INSTALLATION OR MAINTENANCE
READ INSTRUCTIONS CAREFULLY BEFORE ATTEMPTING TO
INSTALL LUMINAIRE. FAILURE TO COMPLY WITH INSTRUCTIONS
COULD RESULT IN PERSONAL INJURY AND/OR PROPERTY DAMAGE
RETAIN INSTRUCTIONS FOR FUTURE REFERENCE.
SEE PAGES 1 AND 2 FOR LUMINAIRE INSTALLATION AND WIRING
INSTALLING LCC-SPC VANDAL SHIELD
* Remove protective film from shield surfaces.
* Open door (C), loosen (2) retaining screws (D).
* From the inside of door, on each (3) bosses (T)
drill door thru using .173" diamter No.17 drill bit (not provided).
* Remove metal chips and close door.
* Install vandal shield using (3)
self threading screws (V) provided.
V
FIG. 13
PTA - EXTERNAL PHOTOCONTROL FIELD INSTALLATION
WARNING: ONLY USE THE FOLLOWING APPROVED FIELD INSTALL
PHOTOCONTROL FOR THIS PRODUCT.
PTA-1 External Photocontrol - 1/2" Thread Mount , 120V
PTA-8 External Photocontrol - 1/2" Thread Mount, 120V to 277V
* Remove hole plug (N) from the side of housing.
* Apply pipe sealant to photocontrol thread to prevent leakage.
* Insert photocontrol wires thru opening.
* Install photocontrol (PTA) on the outside of housing.
* Lock with locknut at correct photocontrol orientation.
* Wiring: Refer to Photocontrol manufacturer wiring instruction
provided with Photocontrol.
Hubbell Lighting, Inc.
A subsidiary of Hubbell Incorporated
701 Millennium Blvd • Greenville, SC 29607
Phone: (864) 678-1000
ACCESSORIES INSTRUCTIONS
LAREDO LCC LUMINAIRE
(Fig. 11)
(Fig. 11)
(Fig. 13)
VANDAL
SHIELD
FIG. 11
(Fig. 12)
6.37
DRILL (3) BOSSES
ON CENTER
T
(Fig. 14)
PAGE 3 OF 8
PAGE 3 DE 8
PAGINA 3 DE 8
D
C
2.60
FIG. 12 - INSIDE DOOR OPEN
APPLY PIPE
SEALANT
N
FIG. 14
Doc. Number:
Revision: *
PTA
93015006