Electrical Safety; Assembly; Install The Pump; Connect The Suction Line - AL-KO JET 3600 Manual De Instrucciones

Tabla de contenido
Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 45

Assembly

less technical condition. Dam-
aged appliances must not be
operated.
Maintain a safe distance to
persons or animals or switch
off the pump if animals ap-
proach.

3.2 Electrical safety

The pump may not be operat-
ed while people are in the
pool or pond.
The mains voltage at your lo-
cation must comply with the
information regarding mains
voltage in the Technical Data.
Do not use any other supply
voltage.
The appliance must only be
operated on electrical equip-
ment in accordance with DIN/
VDE 0100, parts 737, 738 and
702. A circuit breaker of 10 A
must be installed for fuse pro-
tection.
Only use an extension cords
which are designed for out-
door use – minimum cross-
section 3 x 1.5 mm
H07RN-F as per DIN
57282/57245 with splash-
proof plug socket. Always fully
unwind cable drums.
Check the condition of you ex-
tension cable prior to every
use.
477634_a
2
, quality of
4 ASSEMBLY
HW 3600 / HWA 3600
IMPORTANT! Danger of damage to the
pump! The pump will not function correctly if the
tapping point is 15 m higher than the pump.
Ensure that the tapping point is not more
than 15 m above the pump.
4.1

Install the pump

1. Prepare a level and sturdy installation loca-
tion.
2. Install the pump horizontally and where it will
not be flooded.
3. If necessary, bolt down the pump at the bolt-
ing points (01-03/11).
The pump must be protected from rain
and direct water jets.
4. Remove the thread protective cap at the
pump inlet (01-03/7) and pump outlet
(01-03/3).
Keep the protective caps for possible
transport.
IMPORTANT! Risk of flooding! In the event
of faults in the pump,water can escape and
cause consequential damage due to flooding.
Take appropriate measures to avoid conse-
quential damage caused by flooding in the
event of faults in the pump.
4.2

Connect the suction line

NOTE We recommend the installation of
flexible lines at the pump inlet to prevent me-
chanical pressure or tension being exerted on the
pump.
1. Select the length of the suction line such that
the pump cannot run dry. The suction line
must always be at least 30 cm under the wa-
ter surface.
2. Connect the suction line. Ensure that the
connection is tight, but take care not to dam-
age the thread.
3. Always lay the suction line with an upward
gradient.
NOTE If the suction head is more than
4 m, a suction hose with a diameter larger than 1"
must be installed. We recommend the use of an
AL-KO suction unit with suction hose, suction fil-
ter and flow-back stop. Ask your specialist dealer.
19