Broan MP280 Manual De Instrucciones
Broan MP280 Manual De Instrucciones

Broan MP280 Manual De Instrucciones

Ventilador en línea de múltiples tomas
Idiomas disponibles

Idiomas disponibles

Enlaces rápidos

MODEL MP280
MULTI-PORT IN-LINE
VENTILATOR
READ AND SAVE THESE INSTRUCTIONS
WARNING
TO REDUCE THE RISK OF FIRE, ELECTRIC
SHOCK, OR INJURY TO PERSONS, OBSERVE
THE FOLLOWING:
1. Use this unit only in the manner intended by the
manufacturer. If you have questions, contact the
manufacturer at the address or telephone number
listed below the warranty.
2. Before servicing or cleaning unit, switch power off
at service panel and lock the service disconnecting
means to prevent power from being switched on ac-
cidentally. When the service disconnecting means
cannot be locked, securely fasten a prominent warning
device, such as a tag, to the service panel.
3. Installation work and electrical wiring must be done by
qualified person(s) in accordance with all applicable
codes and standards, including fire-rated construction
codes and standards.
4. Sufficient air is needed for proper combustion and
exhausing of gases through the flue (chimney) of fuel
burning equipment to prevent backdrafting. Follow the
heating equipment manufacturer's guideline and safety
standards such as those published by the National
Fire Protection Association (NFPA), and the American
Society for Heating, Refrigeration and Air Conditioning
Engineers (ASHRAE), and the local code authorities.
PLAN THE INSTALLATION
Adequate ventilation requires that both intermittent and
continuous contamination be controlled.
Intermittent ventilation must be provided in the bath-
room and kitchen. The bathroom requires 8 air changes
per hour.
(Multiply bathroom sq. footage by 1.1 for proper fan sizing)
The kitchen requires a minimum of 150 CFM capacity
(71 l/s) when a ducted range hood is used. If a kitchen
fan is used, determine fan capacity by multiplying the
room's sq. footage by 2. All are run intermittently to control
pollution at the source.
Continuous ventilation, while the house is occupied,
provides the flow of fresh air for good indoor air quality.
This ventilator is intended to for continuous operation,
supplying fresh air to the entire house.
WARNING
5. When cutting or drilling into wall or ceiling, do not
damage electrical wiring and other hidden utilities.
6. Ducted fans must always be vented to the outdoors.
7. This unit must be grounded.
CAUTION
1. For general ventilating use only. Do not use to exhaust
hazardous or explosive materials and
vapors.
2. To avoid motor bearing damage and noisy and/or un-
balanced impellers, keep drywall spray, construction
dust, etc. off power unit.
3. If ventilator is installed in an unconditioned space
(such as an attic): Surround the ventilator with thermal
insulation - to minimize possible condensation.
4. Please read specification label on product for
further information and requirements.
RECOMMENDED VENTILATOR SIZING
DWELLING SIZE RANGE (Sq. Ftg.)
(include finished basement area)
MODEL
.50 AC/HR*
MP280
4200
*AC/HR = Air Changes per Hour. Based on 8' ceilings.
Square Feet x .093 = Square Meters
.35 AC/HR*
.30 AC/HR*
6000
7000
Tabla de contenido
loading

Resumen de contenidos para Broan MP280

  • Página 1 MODEL MP280 MULTI-PORT IN-LINE VENTILATOR READ AND SAVE THESE INSTRUCTIONS WARNING WARNING TO REDUCE THE RISK OF FIRE, ELECTRIC 5. When cutting or drilling into wall or ceiling, do not SHOCK, OR INJURY TO PERSONS, OBSERVE damage electrical wiring and other hidden utilities.
  • Página 2 LOCATION OF DIFFUSERS & INLETS PLAN THE INSTALLATION FRESH AIR INLET STALE SINGLE-STORY HOME VENTILATOR FRESH AIR INLETS DIFFUSER DUCTED FRESH KITCHEN RANGE HOOD DIFFUSER DIFFUSER DUCTED AIR FLOW IN TYPICAL INSTALLATION BATH FAN VENTILATOR The ventilator exhausts stale air. There are normally suf- ficient natural intake openings into a dwelling to admit FRESH AIR INLETS fresh outside air to be drawn in to replace the stale air.
  • Página 3 INSTALL FRESH AIR INLETS 2. To minimize condensation inside of ductwork in the attic, cover ductwork with additional insulation. Also, avoid forming condensation traps in the ductwork runs. 1. Mount all fresh air inlets in chosen locations during rough-in construction. Follow directions packed with 3.
  • Página 4: Service Parts

    This warranty gives you specific legal rights, and you may also have other rights, which vary from state to state. This warranty supersedes all prior warranties. To qualify for warranty service, you must (a) notify Broan-NuTone at the address or telephone number below, (b) give the model number and part identification and (c) describe the nature of any defect in the product or part. At the time of requesting warranty service, you must present evidence of the original purchase date.
  • Página 5: Modelo Mp280 Ventilador En Línea De Múltiples Tomas

    MODELO MP280 VENTILADOR EN LÍNEA DE MÚLTIPLES TOMAS LEA Y CONSERVE ESTAS INSTRUCCIONES ADVERTENCIA ADVERTENCIA PARA REDUCIR EL RIESGO DE INCENDIOS, (National Fire Protection Association, NFPA), la Sociedad DESCARGAS ELÉCTRICAS O LESIONES Americana de Ingenieros de Calefacción, Refrigeración PERSONALES, OBSERVE LAS SIGUIENTES...
  • Página 6: Ubicación De Difusoresy Entradas

    UBICACIÓN DE DIFUSORES PLANEACIÓN DE LA INSTALACIÓN Y ENTRADAS ENTRADA DE AIRE FRESCO AIRE VICIADO CASA DE UN PISO VENTILADOR ENTRADAS DE AIRE FRESCO DIFUSOR AIRE CAMPANA DE FRESCO COCINA CON CONDUCTOS DIFUSOR DIFUSOR VENTILADOR FLUJO DE AIRE EN UNA INSTALACIÓN TÍPICA DE BAÑO VENTILADOR CONDUCTOS...
  • Página 7: Instale Entradas De Aire Fresco

    INSTALE ENTRADAS DE El lado de salida está marcado con una etiqueta. AIRE FRESCO 2. Para minimizar la condensación por dentro de los conductos en el ático, cubra los conductos con 1. Monte todas las entradas de aire fresco en ubicaciones aislamiento adicional.
  • Página 8: Instale Los Difusores De Extracción

    GARANTÍA BROAN-NUTONE LIMITADA POR UN AÑO Broan-NuTone garantiza al consumidor comprador original de sus productos que dichos productos carecerán de defectos en materiales o en mano de obra por un período de un año a partir de la fecha original de compra. NO EXISTEN OTRAS GARANTÍAS, EXPLICITAS O IMPLÍCITAS, INCLUYENDO, ENTRE OTRAS, GARANTÍAS IMPLÍCITAS DE COMERCIALIZACIÓN O APTITUD PARA UN PROPÓSITO PARTICULAR.

Tabla de contenido