Sediment Trap Assembly

Assemble the tee, nipples and cap together and
tighten securely. See Fig. 5. The sediment trap
assembly must always be mounted in a vertical
position. Make sure pipe thread compound that is
resistant to both L.P. gas and natural gas is used
in making all connections. Check all connec-
tions for gas leaks using approved gas
leak detectors.
FIG. 5
NIPPLE
TO GAS CONTROL
VALVE INLET
Guardian with Smart Sense™
Manual Shut-off Valve,
Hose & Regulator
Assembly
1. Always use approved pipe thread compound
suitable for use with L.P. gas or natural gas on
the threaded connections.
2. Assemble the components together accord-
ing to the fi gure. This view is to show general
assembly of the components only. The regulator
must always be mounted so its vent, regardless
HOSE ADAPTER
of location on the regulator, is always pointed
downward.
TEE
3. Tighten all connections securely.
NIPPLE
4. Check all connections for gas leaks
using approved gas leak detectors.
CAP
FIG. 6
REGULATOR VENT
TO CONTROL
VALVE INLET
Owner's Manual • Guardian
REGULATOR
NIPPLE
VALVE, MANUAL
SHUT-OFF
GAS HOSE
ADAPTER