Technical parameters
AirPD-100S
Power supply
Battery power:
Battery life:
Battery status view:
Setting
Setting:
Measured values:
Detection
Detection principle:
Detection distance:
Theft detection:
Temperature measurement:
Input
Temperature measuring:
Range:
Sensitivity:
Accuracy:
Communication
Protocol:
Transmitter frequency:
Range in open space:
Protocol:
Transmitter frequency:
RCZ1 868 MHz
Range in open space:
Approx. 50 km** Approx. 10 km** Approx. 30 km**
Transmission power (max.):
25 mW / 14 dBm 25 mW / 14 dBm 200 mW / 23 dBm
Other parameters
Working temperature:
Operating position:
Pressure load:
Protection degree:
Resistance to external
infl uences:
Dimension:
Weight:
* Depending on network coverage
** Multiple frequency bands of B1 / B3 / B5 / B8 / B20 / B28
*** Minimum distance from metal objects (canal) – 1m.
Warning
Read the operating instructions before installing the device and putting it into opera-
tion. Instruction manual is designated for mounting and also for user of the device. It is
always a part of its packing. Installation and connection can be carried out only by a per-
son with adequate professional qualifi cation upon understanding this instruction man-
ual and functions of the device, and while observing all valid regulations. Trouble-free
function of the device also depends on transportation, storing and handling. In case you
notice any sign of damage, deformation, malfunction or missing part, do not install this
device and return it to its seller. It is necessary to treat this product and its parts as elec-
tronic waste after its lifetime is terminated. Before starting installation, make sure that all
wires, connected parts or terminals are de-energized. While mounting and servicing ob-
serve safety regulations, norms, directives and professional, and export regulations for
working with electrical devices. Do not touch parts of the device that are energized – life
threat. To ensure the transmission of the radio signal, make sure that the devices in the
building where the installation is installed are correctly located. Unless otherwise stated,
the devices are not intended for installation in outdoor and damp areas, they must not
be installed in metal switchboards or in plastic cabinets with metal doors - this prevents
transmission of the radio frequency signal. iNELS Air is not recommended for control-
ling life-saving instruments or for controlling hazardous devices such as pumps, heaters
without thermostat, lifts, hoists, etc. - radio frequency transmission may be overshad-
owed by obstruction, interference, transmitter battery may be discharged etc., thereby
disabling the remote control.
AirPD-100L
AirPD-100NB
non-removable battery
2x 3.6V Li-SOCL
2
Approx. 10 years, depending on the setting
message to the server
With a message from the server, magnetic keys,
RFAF/USB Service Key
message to the server
magnetic
0 - 50 cm
yes
yes
built-in sensor
-30 .. 85 °C
1 °C
± 3 °C
iNELS RF Control
868.5 MHz
up to 100 m
Sigfox
LoRa
868 MHz
LTE Cat NB1*
-30 ... + 85 °C
Push into the road (ground level)***
up to 1 000 kg
IP68
UV, salt, snow plough
Ø 87 x 62 mm
432 g
Assembly
1. Drill a hole of approx. 90 mm diameter and 65 mm depth in the ground at the desired
location with a suitable tool.
2. Fill the hole with the desired fi xing compound (according to the substrate and insert the
detector so that it is level with the surface.
3. Refi ll or remove any excess, and allow the compound to set.
Recommendations for installation
• The detector is suitable for outdoor use. Operating conditions are consistent with con-
ventional chemically non-aggressive environments.
• Before mounting, check the range. Ensure the correct location - see Warning.
• The recommended working orientation is vertical, magnetic contacts upright towards
the detection area.
• The detector's immediate surroundings must remain free for proper detection. The mini-
mum distance from metal objects (e.g. channel cover, track ...) is 1m.
NB-IoT
• Do not cover the detector as this may reduce signal transmission.
Commissioning
To activate the detector, place the magnet on the POWER-ON magnetic contact for 5 sec-
onds and then on the magnetic contact SET for 3 seconds. The detector sends a start
message.
After activation, calibrate the detector by applying the magnet to the SET magnetic con-
tact for 9 seconds. After successful calibration (15 seconds), the detector sends a mes-
sage.
You can also perform calibration and detector setup in the application or using the RFAF/
USB Service Key and to lock the detector against manual adjustment.
2 / 2