Installation
NOTICE: Be sure discharge port lines up with
hole in base.
12. NOTICE: Tighten nuts as follows:
A. Hand tighten all nuts.
B. Tighten one nut snug.
C. Tighten opposite nut snug.
D. Proceed, tightening opposite pairs of nuts to
a snug fit.
E. Recheck all nuts, using same pattern. Be sure
all nuts are tight and that you have a good
seal.
NOTICE: Do not overtighten; you may twist
studs off of tank. If you have a torque
wrench, tighten to 85 inch-pounds torque.
13. Stand tank on feet and reconnect piping.
14. Recharge tank to proper air pressure (see Page
4).
15. Prime pump (see pump owner's manual).
AIR VALVE REPLACEMENT
Hazardous Pressure. To be sure air
valve and core cannot blow out of tank, release all
air pressure from tank before removing valve core
or valve.
1. Disconnect power to pump.
2. Drain ALL water in system by opening faucet
closest to tank.
3. Depress valve core to release ALL air pressure
in tank. When air stops coming out of valve,
remove core from inside of valve to release
remaining pressure.
4. Push air valve back into tank. Be sure to
remove it before reassembling tank.
5. Disconnect piping from tank and turn it on its
side.
SUBMERSIBLE AND MULTI-STAGE INSTALLATIONS
Tank with Submersible Pump
Pressure
Pressure
Gauge
Switch
From Well
160 0893
PIPING CONNECTIONS
NOTE: When using metal pipe with plastic fittings use only
Teflon tape or Plasto-Joint Stik on male threads.
To service
Pressure
Relief Valve
6. Remove flange from tank.
7. Push bladder into tank far enough so that you
can get into tank with a dowel rod.
8. Soap the outside of the new valve and mount it
on the end of a piece of 1/4" or 5/16" dowel
rod. Push the valve up past the bladder into its
mounting hole in the top of the tank. Push it
through as far as it will conveniently go; leave
the valve cap on to protect the threads on the
valve.
9. Rap the end of the dowel sharply with a ham-
mer to drive the valve into position. Be sure the
shoulder on the valve seats against the tank
head (the ridge around the valve body should
be all the way through the hole in the tank
head – see Figure 6).
Figure 6 – Tap valve into place
10. Remove the dowel. Make sure the old valve has
been removed from the tank, pull bladder back
over rim of hole in lower tank head, reinstall
flange, stand tank upright and reconnect piping.
11. Recharge tank (see Page 4), turn on power, fill
system, and tank is ready for service.
Tank with Multi-Stage Pump
Pressure
Relief Valve
To Service
2869 0697
6