Technical Specifications - CEMB TV-32 Manual Del Usuario

Tabla de contenido
Idiomas disponibles

Idiomas disponibles

3.
t
echnical speciFications
Sensor type
Measure type
Dynamic range
Frequency response
Vibrations direction
Sensitivity (± 10%)
Resonant frequency
Max. shock protection
Setting time
Power supply
Max. output impedance
Electrical case isolation
Electromagnetic sensitivity
Temperature range
Case material
Mounting hole
Weigth
External protection
Connection
Maintenance
Drawings enclosed
4.
a
ssembly
Prepare a smooth, flat mounting surface and then drill and tap a mounting hole in the center of this area.
Wipe clean the mounting surface and spread on a light film of grease, oil or similarcoupling fluid prior to installation.
Avoid giving violent shocks to the body of the transducer; the tightening torque should be 2.7 ÷
4
PZT piezoelectrical velocimeter
Seismic (absolute vibrations)
±254 mm/s-pk ± 50 in/sec-pk
: ± 3 db 1,0÷10000 Hz 60÷600.000 CPM
any
20 mV/mm/s
500 mV/in/sec
25000 Hz
1.500.000 CPM
5000 g pk
> 4"
> 4 sec
2÷10 mA - 18÷30 Vdc
< 100 ohm
>10 (8) Ohm
Certified CE
-50°C ÷ +121°C -58°F÷+250°F
stainless steel 316L
standard = ¼"-28UNF-2B (or to be specify with the order)
90 grm
3.2 oz
IP65 EN60529/10.91 standards
2 pin MIL-C-5015 serial 3106/10, included connector
none
73920P= overall dimensions, layout and electrical connec-
tions