HP-160L / HP-200PP / HP-250PP
Health and Safety
Environment
1. The machine can perform in environments where conditions are dry with a maximum humidity level of
90% and an ambient temperature between -10 to +40 degrees centigrade.
2. Avoid welding in direct sunshine or a wet/damp environment. If the machine comes into contact with
water, do not use the machine until it has been fully inspected by a qualified professional.
3. Do not use the machine in an environment where the air is polluted with conductive dust.
Technical Data
Power Input AC
Power Phase
Frequency (HZ)
Rated Input Current (A)
No-load (V)
Output Current (A)
Rated Working (V)
Duty Cycle (%)
No-load Loss
Efficiency (%)
Power Factor
Insulation Grade
Housing Protection
HP-160L
230V ±15% AC
Single Phase
50/60
24
56
20~160
16.4
60
40
85
0.73
F
IP21
© ROHR
English
HP-200PP
230V ±15% AC
Single Phase
50/60
32
56
20~200
18
60
40
85
0.73
F
IP21
HP-250PP
230V ±15%
Single Phase
50/60
34
56
20~250
20
60
40
85
0.73
F
IP21
7