FCC/IC - EN
This device complies with Part 15 of the FCC and Industry Canada license-exempt RSS
standards. Operation is subject to the following two conditions: (1) this device may not cause
harmful interference, and (2) this device must accept any interference received, including
interference that may cause undesired operation.
FCC NOTE: The manufacturer is not responsible for any radio or TV interference caused by
unauthorized modifications to this equipment. Such modifications could void the user's
authority to operate the equipment
NOTE: This equipment has been tested and found to comply with the limits for a Class B
digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide
reasonable protection against harmful interference in a residential installation. This
equipment generates, uses and can radiate radio frequency energy, and if not installed
and used in accordance with the instructions, may cause harmful interference to radio
communications. However, there is no guarantee interference will not occur in a particular
installation. If this equipment does cause harmful interference to radio or television reception,
which can be determined by turning the equipment off and on, the user is encouraged to try to
correct the interference by one or more of the following measures:
— Reorient or relocate the receiving antenna.
— Increase the separation between the equipment and receiver.
— Connect the equipment into an outlet on a circuit different to which the receiver is connected.
— Consult the dealer or an experienced radio/TV technician for help.
Important note: To comply with the FCC RF exposure compliance requirements, no change to
the antenna or the device is permitted. Any change to the antenna or the device could result
in the device exceeding the RF exposure requirements and void user's authority to operate
the device.
FCC /IC - FR
Cet appareil est conforme au paragraphe 15 des normes FCC et au CNR pour les appareils
exempts de licence d'Industrie Canada. Son utilisation est sujette aux deux conditions
suivantes (1) cet appareil ne doit pas occasionner de brouillage préjudiciable et (2) cet
appareil doit accepter toutes les interférences reçues, notamment les interférences qui
peuvent provoquer un fonctionnement non désiré.
REMARQUE DE LA FCC : Le fabricant n'est pas responsable des interférences sur les
fréquences radioélectriques ou télévisuelles pouvant être causées par des modifications non
autorisées de ce matériel. De telles modifications peuvent annuler le droit de l'utilisateur à
utiliser cet appareil.
REMARQUE : Cet appareil a été testé et certifié conforme aux limites relatives aux appareils
numériques de catégorie B définies dans le paragraphe 15 des normes FCC. Ces limites ont
été définies afin de fournir une protection raisonnable contre le brouillage préjudiciable en
milieu résidentiel. Cet appareil produit, utilise et peut émettre des ondes de fréquence radio et,
s'il n'est pas installé et utilisé conformément aux instructions, il peut provoquer un brouillage
préjudiciable aux communications radio. Il n'existe toutefois aucune garantie que des
interférences ne se produiront pas dans une installation donnée. Si cet appareil occasionne
un brouillage préjudiciable à la réception radiophonique ou télévisuelle, il suffit d'allumer
et d'éteindre l'appareil pour déterminer sa responsabilité. Nous encourageons l'utilisateur à
essayer de corriger ces interférences en appliquant une ou plusieurs des mesures suivantes :
— Réorienter ou déplacer l'antenne de réception.
— Augmenter la distance entre l'appareil et le récepteur.
— Brancher l'appareil à une prise secteur différente de celle du récepteur.
— Pour obtenir de l'aide, consulter le revendeur ou un technicien spécialisé en postes radio
ou téléviseurs.
Remarque importante : Pour se conformer aux exigences de conformité de la FCC concernant
l'exposition aux RF, aucune modification apportée à l'antenne ou au dispositif n'est autorisée.
Toute modification apportée à l'antenne ou au dispositif pourrait faire en sorte que le
dispositif dépasse les exigences d'exposition aux RF et pourrait annuler le droit de l'utilisateur
à utiliser ce dispositif.
FCC/IC - ES
Este dispositivo cumple con las Especificaciones del apartado 15 de las normas de la FCC
y con las especificaciones de las normas radioeléctricas (RSS) del Ministerio de Industria
de Canadá aplicables a aparatos exentos de licencia. El funcionamiento está sujeto a las
siguientes dos condiciones: (1) este dispositivo no debe provocar interferencia perjudicial, y
(2) este dispositivo debe aceptar toda interferencia que reciba, incluso la que pudiera causar
un funcionamiento no deseado.
NOTA DE LA FCC: El fabricante no se hace responsable de ninguna interferencia de radio
o TV ocasionada por modificaciones no autorizadas efectuadas a este equipo. Dichas
modificaciones podrían anular la autoridad del usuario para utilizar el equipo.
NOTA: Este equipo ha sido probado y cumple con los límites para aparatos digitales de
Clase B, de conformidad con el apartado 15 de las normas de la FCC. Estos límites están
diseñados para proveer protección razonable contra interferencias perjudiciales en una
instalación residencial. Este equipo genera, usa y puede irradiar energía de radiofrecuencias
y, si no se instala y usa según las instrucciones, puede provocar interferencia perjudicial a
las radiocomunicaciones. No obstante, no hay garantías de que no ocurrirá interferencia en
una instalación en particular. Si este equipo provoca interferencia perjudicial a la recepción
de radio o televisión, lo que puede determinarse encendiendo y apagando el equipo, se
recomienda que el usuario intente corregir la interferencia por medio de la implementación de
una o más de las siguientes medidas:
— Reorientar o reubicar la antena receptora.
— Incrementar la separación entre el equipo y el receptor.
— Conectar el equipo a un tomacorriente de un circuito diferente del circuito al que está
conectado el receptor.
— Consultar al distribuidor o a un técnico con experiencia en radio/televisión para
solicitar asistencia.
Nota importante: Para cumplir con los requisitos de cumplimiento de exposición de
radiofrecuencia de la FCC, no se permiten cambios a la antena o el dispositivo. Cualquier
cambio a la antena o dispositivo podría hacer que el dispositivo supere los requerimientos de
exposición de radiofrecuencia y anular la autoridad del usuario para operar el dispositivo.
Responsible Party - US Contact Information | Parte responsable - Información de contacto
de los Estados Unidos | Partie responsable - Coordonnées des États-Unis
FCC — U2ZZW3010 | IC: 6924A-ZW3010
Jasco Products Company | Model: ZW3010/39351
10 E. Memorial Rd., Oklahoma City, OK 73114 | 1-800-654-8483
CAN ICES-3(B)/NMB-3(B)
All brand names shown are
Tous les noms de marque illustrés
Todas las marcas que aparecen
trademarks of their respective owners.
sont des marques de commerce
aquí son marcas registradas
de leurs propriétaires respectifs.
de sus respectivos dueños
The Honeywell Trademark is used under license from Honeywell International
Inc.
Honeywell International Inc. makes no representation or warranties with
respect to this product.
This product is manufactured by Jasco Products Company LLC.
MADE IN CHINA/FABRIQUÉ EN CHINE/HECHO EN CHINA
©JASCO 2019 | 39351 | ZW3010 | 06/05/19 v3
Jasco Products Company LLC.
10 E. Memorial Rd.,
Oklahoma City, OK 73114
1
TOOLS
IMPORTANT!
The fixture controlled by the Z-Wave In-Wall Smart Dimmer must not exceed 600 watts
(incandescent); 300W dimmable CFL/LED. The dimmer is designed only for use with
permanently installed fixtures.
2
FEATURES
• Turn ON/OFF and adjust dim levels manually or remotely via the
Z-Wave controller
• Can be added in multiple groups and scenes
• May be used in single-pole installation or with up to four Honeywell
Add-on Switches in 3-way or 4-way wiring configurations
• Compatible with all incandescent and most dimmable CFL/LED bulbs
• Auto line/load detection
• Interchangeable paddle switch — white & light almond paddle in package
• Uses a standard, decorative-style wallplate for single-gang installations
(wallplate not included)
• Blue LED indicates switch location in a dark room
• Z-Wave certified for simple pairing and integrated home automation
• Screw terminal installation — requires wiring connections for line (hot),
load, neutral and ground. Traveler wire required for 3-way or 4-way
installation
• This Z-Wave device has advanced features that allow you to customize
your experience. These features can only be adjusted by a Z-Wave enabled
controller that supports the Z-Wave configuration command class. For a
complete list of adjustable configurations,
visit www.honeywellelectricalaccessories.com
LED bulb adjustments
Not all LED bulbs are made the same, and performance varies between
dimmer brands. This can cause adverse bulb behavior, such as flickering or
strobing. To account for this scenario, this dimmer features adjustable dim
and brightness thresholds to allow setting minimum and maximum levels.
Minimum dim threshold
1. Press OFF button four times, then ON button once quickly.
2. Light starts at the most recent dim level (default — 1%).
3. Press the ON or OFF button until the bulb reaches
desired brightness without flickering.
4. The LED stops flashing 10 seconds after releasing the
button to indicate the minimum threshold is set.
Note: This can be set by Z-Wave configuration parameter
30/size: 1 byte/values 1-99 (default — 1)
Maximum brightness threshold
1. Press ON button four times, then OFF button once quickly.
2. Light starts at the most recent brightness (default — 99%)
3. Press the ON or OFF button until the bulb reaches
desired brightness without flickering.
4. The LED stops flashing 10 seconds after releasing the
button to indicate the maximum threshold is set.
Note: This can be set by Z-Wave configuration parameter 31/size: 1byte/values 1-99 (default —99)
A
F
B
D
G
C
E
A.
Ground (Green/Bare)
F.
Top rocker — Press & release to
turn dimmer ON, press & hold to
B.
Line or Load (Black)
increase brightness
C.
Line or Load (Black)
G.
Bottom rocker — Press &
D.
Traveler (Red/Other)
release to turn dimmer OFF,
E.
Neutral (White)
press & hold to dim
READ IT OR WATCH IT
Read instructions or watch easy-to-follow
video. Scan QR code or visit goo.gl/EsFevp
SMART DIMMER
IN-WALL
INTELLIGENT GRADATEUR
MONTAGE MURAL
INTERRUPTOR
REDUCTOR
DE PARED
LUZ INTELIGENTE
DE
Z-W
® C
W
l
C
ave
ertified
ireless
ighting
ontrol
Z-W
® C
i
i
ave
ontrol de
luminaCión
nalámbriCo CertifiCado
C
Z-W
®
ontrol inalámbriCo para iluminaCión CertifiCado por
ave
Purchase additional items at
honeywellelectricalaccessories.com
or visit your local retailer.
In-Wall
Plug-in
Smart Switches
Smart Swtiches
Plug-in
In-Wall
Smart Dimmers
Smart Dimmers
In-Wall
Plug-in
Smart Fan Control
Outdoor
Smart Switch
In-Wall
In-Wall
Add-on Switches
Tamper-Resistant
Smart Outlet
3
INSTALLATION
1
1
2
3
4
OUT TO
LIGHT (LOAD)
B
A
D
E
C
5
7
FROM BREAKER BOX
out to light (load)
A
B
D
E
C
from breaKer boX
10 11
8
9
12 13
14
DO NOT RETURN THIS
PRODUCT TO THE STORE
NE RETOURNEZ PAS
STOP
CE PRODUIT AU MAGASIN
NO DEVUELVA ESTE
PRODUCTO A LA TIENDA
If you have any problems or questions, contact our tech support
team at 1-855-698-8324, Monday–Friday, 7AM–8PM CST.
For the most up-to-date product support, accessories, electronic
(PDF) format manuals and more, visit www.byjasco.com/support.
• No user serviceable parts in this unit.
Si vous avez des problèmes ou des questions, communiquez
avec notre équipe de soutien technique au 1-855-698-8324,
option 1, du lundi au vendredi, de 7 h à 20 h (HNC).
Pour le soutien relatif aux produits le plus à jour, les
accessoires, les manuels en format électronique (PDF) et
plus encore, visitez le site www.byjasco.com/support.
• Aucune des pièces de ce dispositif ne peut être réparée par l'utilisateur.
Si tiene problemas o dudas, comuníquese con nuestro equipo
técnico al número: 1-855-698-8324, opción 1 de lunes a viernes,
de 7 a.m. a 8 p.m., hora estándar del centro (CST).
Para recibir el soporte técnico más actualizado sobre productos, accesorios,
manuales en formato digital (PDF), entre otros, visite www.byjasco.com/support.
• Esta unidad no contiene piezas que el usuario pueda reparar.
WARNING
ADVERTENCIA
RISK OF FIRE
RIESGO DE INCENDIO
RISK OF ELECTRICAL SHOCK
RIESGO DE DESCARGA ELÉCTRICA
RISK OF BURNS
RIESGO DE QUEMADURAS
CONTROLLING APPLIANCES
CONTROL DE EQUIPOS
CAUTION: TO REDUCE THE RISK OF
ELECTRODOMÉSTICOS
OVERHEATING AND POSSIBLE DAMAGE
PRECAUCIÓN: A FIN DE DISMINUIR
TO OTHER EQUIPMENT, DO NOT
EL RIESGO DE RECALENTAMIENTO
INSTALL TO CONTROL A RECEPTACLE,
Y DE POSIBLES DAÑOS EN LOS
A MOTOR-OPERATED APPLIANCE,
DEMÁS EQUIPOS, NO INSTALAR
FLUORESCENT LIGHTING FIXTURE, OR
PARA CONTROLAR APARATOS QUE
TRANSFORMER-SUPPLIED APPLIANCE.
FUNCIONAN A MOTOR, ARTEFACTOS DE
ILUMINACIÓN DE LUZ FLUORESCENTE
• ONLY USE TO CONTROL INCANDESCENT
O APARATOS ALIMENTADOS
OR DIMMABLE CFL/LED BULBS
39351
CON TRANSFORMADORES.
• DO NOT EXCEED RATINGS
• USAR EXCLUSIVAMENTE PARA
ZW3010
• DO NOT USE TO CONTROL ANY DEVICE
CONTROLAR BOMBILLAS CFL/LED
WHERE UNINTENDED OPERATION
INCANDESCENTES O ATENUABLES
COULD CAUSE UNSAFE CONDITIONS
• NO SUPERE LOS VALORES
(HEAT LAMP, SUN LAMP, ETC.)
NOMINALES ELÉCTRICOS
• FOR INDOOR USE ONLY
• NO USAR PARA CONTROLAR
DISPOSITIVOS
AVERTISSEMENT
• USE SOLAMENTE EN INTERIORES
RISQUE D'INCENDIE
NOT FOR USE WITH MEDICAL OR
RISQUE DE CHOC ÉLECTRIQUE
LIFE-SUPPORT EQUIPMENT
RISQUE DE BRÛLURES
Z-WAVE ENABLED DEVICES SHOULD
NEVER BE USED TO SUPPLY
COMMANDE DES APPAREILS:
POWER TO OR CONTROL THE ON/
ATTENTION: POUR RÉDUIRE LE RISQUE
OFF STATUS OF MEDICAL AND
DE SURCHAUFFE ET DE DOMMAGES
LIFE-SUPPORT EQUIPMENT.
POSSIBLES À D'AUTRES APPAREILS, NE
PAS INSTALLER POUR COMMANDER
NE PAS UTILISER AVEC UN
UN APPAREIL ACTIONNÉ PAR
ÉQUIPEMENT MÉDICAL
MOTEUR, UN APPAREIL D'ÉCLAIRAGE
FLUORESCENT OU UN APPAREIL
OU DE SURVIE
ALIMENTÉ PAR UN TRANSFORMATEUR.
LES DISPOSITIFS COMPATIBLES
AVEC LA TECHNOLOGIE Z-WAVE NE
• UTILISER SEULEMENT POUR
COMMANDER LES AMPOULES À DEL ET
DEVRAIENT JAMAIS ÊTRE UTILISÉS
POUR ALIMENTER OU COMMANDER
FLUOCOMPACTES À INCANDESCENCE
OU À INTENSITÉ RÉGLABLE
LA MISE EN MARCHE OU L'ARRÊT DE
L'ÉQUIPEMENT MÉDICAL OU DE SURVIE.
• NE PAS DÉPASSER LES
CARACTÉRISTIQUES NOMINALES
• NE PAS UTILISER POUR COMMANDER
SE PROHÍBE SU EMPLEO EN
DES APPAREILS POUR LESQUELS
EQUIPO MÉDICO O EQUIPO
UN FONCTIONNEMENT IMPRÉVU
PARA EL MANTENIMIENTO DE
POURRAIT ENTRAÎNER DES CONDITIONS
LAS FUNCIONES VITALES
DANGEREUSES (LAMPE À RAYONS
LOS DISPOSITIVOS Z-WAVE NUNCA
INFRAROUGES, LAMPE SOLAIRE, ETC.)
SE DEBEN USAR PARA SUMINISTRAR
• POUR UTILISATION INTÉRIEURE
ENERGÍA ELÉCTRICA AL EQUIPO MÉDICO
UNIQUEMENT
O AL EQUIPO PARA EL MANTENIMIENTO
DE FUNCIONES VITALES, NI PARA
CONTROLAR EL ESTADO DE ENCENDIDO
O APAGADO DE DICHOS EQUIPOS.
WARNING — SHOCK HAZARD
Turn OFF the power to the branch circuit for the switch and lighting fixture at the service
panel. All wiring connections must be made with the POWER OFF to avoid personal injury and
damage to the switch. This device is intended for installation in accordance with the National
Electric Code and local regulations in the United States or the Canadian Electrical Code
and local regulations in Canada. If you are unsure or uncomfortable about performing this
installation, consult a qualified electrician.
MULTI-SWITCH WIRING
The Honeywell add-on switch is required for multi-switch 3-way or 4-way
installations. Connecting the traveler terminal of this switch to a standard, non-
Honeywell switch will cause damage or result in improper function. If this switch
is a part of a 3-way or 4-way multi-switch installation, do not connect the traveler
wire or apply power until Honeywell add-on switches are correctly installed. For
more information on 3-way or 4-way installations, view the manual or quick-start
guide that comes with the Honeywell add-on switch.
SINGLE-SWITCH WIRING
Before you start, you may wish to change the paddle color to match your
wallplate or decor. Please proceed to Section 5
1.
Shut off power to the circuit at circuit breaker or fuse box.
IMPORTANT! Verify power is OFF to switch box before continuing.
2.
Remove wallplate.
3.
Remove the switch mounting screws.
4.
Carefully remove the switch from the switch box. DO NOT disconnect
the wires.
5.
There are up to five screw terminals on the dimmer; these are marked:
A. GROUND — Green/Bare.
B. LINE OR LOAD — Black (connected to power or lighting)
C. LINE OR LOAD — Black (connected to power or lighting)
D. TRAVELER — Red/Other (only in 3-way installations).
E. NEUTRAL — White.
Match these screw terminals to the wires connected to the
existing switch.
6.
Disconnect the wires from the existing switch. Label wires according to
the previous terminal connection.
OBSERVE IMPORTANT WIRING INFORMATION
IMPORTANT ! This dimmer is rated for and intended to only be used with copper wire.
WIRE GAUGE REQUIREMENTS
Use 14 AWG or larger wires suitable for at least 80° C for supplying line (hot),
load, neutral, ground and traveler connections.
WIRE STRIP LENGTH
7.
For attachment to screw terminals strip insulation 1in. (25mm).
For attachment using the enclosure's holes strip insulation 5/8in. (16mm).
UL specifies that the tightening torque for the screws is
12 lbf-in (14 Kgf-cm).
8.
Connect the green or bare copper ground wire to the GROUND
terminal.
9.
Connect the black wire from the light to either LINE/LOAD terminal.
10.
Connect the black wire from the electrical service panel (hot) to either
LINE/LOAD terminal.
11.
Connect the white wire to the neutral terminal (use a jumper wire if needed).
Note: The traveler terminal is only used for 3-way or 4-way wiring and
should remain insulated if the switch is being installed in a single-pole
installation (one switch & one load).
12.
Insert dimmer into the switch box being careful not to pinch or crush wires.
13.
Secure the dimmer to the box using the supplied screws.
14.
Mount the wallplate.
15.
Reapply power to the circuit at fuse box or circuit breaker and test
the system.
BASIC OPERATION
The connected light can be turned ON/OFF in two ways:
1.
Manually from the front panel of the In-Wall Dimmer.
2.
Remotely with a Z-Wave controller.
MANUAL CONTROL
The front panel rocker switch allows the user to turn ON/OFF the
connected fixture.
• To turn the connected fixture ON: Press and release the top of the rocker.
• To turn the connected fixture OFF: Press and release the bottom of
the rocker.
ADJUST DIM LEVELS
1.
To increase brightness: Press and hold the top of the rocker.
2.
To decrease brightness: Press and hold the bottom of the rocker.
CYCLE LED LIGHT
The LED below the dimmer acts as a guide light or status indicator.
How to cycle through options: Press up three times and down once quickly.
1.
LED is ON when the load is OFF (guide light in the dark) (default)
2.
LED is ON when the load is ON (indicates the dimmer is ON)
3.
LED is always OFF
4.
LED is always ON (illuminates dimmer in the dark)
WARRANTY
Jasco Products warrants this product to be free from manufacturing defects for two years
from the original date of consumer purchase. This warranty is limited to the repair or
replacement of this product only and does not extend to consequential or incidental damage
to other products that may be used with this product. This warranty is in lieu of all other
warranties, expressed or implied. Some states do not allow limitations on how long an implied
warranty lasts or permit the exclusion or limitation of incidental or consequential damage, so
the above limitations may not apply to you. This warranty gives you specific rights and you
may also have other rights which vary from state to state. Please contact Customer Service at
1-855-698-8324 between 7AM – 8PM CST or via www.byjasco.com if the unit should prove
defective within the warranty period.
GARANTIE
Jasco Products garantit que ce produit est exempt de tout défaut de fabrication pour une
période de deux ans à compter de la date de l'achat original par l'acheteur. Cette garantie
se limite exclusivement à la réparation ou au remplacement de ce produit et n'est pas
applicable aux dommages indirects ou accessoires survenus sur d'autres produits utilisés
avec ce produit. Cette garantie se substitue à toute autre garantie expresse ou implicite.
Certains États ne permettent pas de restrictions quant à la durée d'une garantie implicite ou
permettent l'exclusion ou la limitation des dommages indirects et accessoires; il se peut, par
conséquent, que cette garantie ne s'applique pas dans votre cas. Cette garantie vous confère
des droits juridiques précis; vous pouvez jouir d'autres droits qui peuvent varier d'un État à
l'autre. Veuillez communiquer avec le service à la clientèle au 1-855-698-8324 entre 7 h et
20 h (heure normale du Centre) ou par l'intermédiaire de notre site web (www.byjasco.com) si
l'appareil s'avère défaillant au cours de la période de garantie.
GARANTÍA
Jasco Products garantiza que este producto está libre de defectos de fabricación durante
un periodo de dos años a partir de la fecha original de compra por parte del consumidor.
Esta garantía se limita a la reparación o sustitución de este producto solamente y no se
extiende a daños derivados o accidentales causados a otros productos que se usen con esta
unidad. Esa garantía remplaza a todas las demás garantías expresas o implícitas. Algunos
estados no autorizan limitaciones en cuanto a la duración de una garantía implícita ni
permiten la exclusión o limitación por daños accidentales o derivados; por lo tanto, puede
que las anteriores limitaciones no apliquen en su caso. Esta garantía le da a usted derechos
específicos, y otros que usted puede tener y que varían según el estado en el que usted reside.
Si la unidad resultare defectuosa dentro del periodo de garantía, comuníquese por favor con
Atención al Cliente en el 855-698-8324 entre 7 y 20 h, Hora del Centro, o a través de nuestro
sitio de internet (www.byjasco.com).
Jasco Products Company LLC, Building B
10 E. Memorial Rd. Oklahoma City, OK 73114.
SPECIFICATIONS
ZW3010
Power: 120VAC, 60Hz.
Signal (Frequency): 908.4/916MHz
Maximum Loads: 1-gang 600W, 2-gang 500W or 3-gang 400W incandescent, 300W
dimmable CFL/LED
Range: Up to 150ft. line of sight between the Wireless Controller and the closest Z-Wave
receiver module.
Operating Temperature Range: 32-104° F (0-40° C)
For indoor use only.
Specifications subject to change without notice due to continuing product improvement
SPÉCIFICATIONS
ZW3010
Tension : 120VCA, 60Hz.
Signal (fréquence) : 908.4/916MHz
Charges maximales : 1 compartiments 600W, 2 compartiments 500W,
3 compartiments 400 W lampes à incandescent 300W CFL/LED
Portée : Distance à vue entre la télécommande et le module de réception Z-Wave le plus
proche allant jusqu'à 150 pi (45,72m).
Plage de températures de fonctionnement : de 0 à 40 °C (de 32 à 104 °F).
Utilisation intérieure uniquement.
En raison d'améliorations continues du produit, les spécifications peuvent faire l'objet de
changements sans préavis.
ESPECIFICACIONES
ZW3010
Alimentación: 120VAC, 60Hz.
Señal (frecuencia): 908.4/916MHz
Cargas máximas: Caja para 1 conexiones 600W, Caja para 2 conexiones 500W,
Caja para 3 conexiones 400W sólo las lámparas incandescente 300W CFL/LED
Alcance: Hasta 150 pies (45,72m) en línea de visión directa entre el control remoto
inalámbrico y el módulo receptor Z-Wave más cercano.
Rango de temperatura de funcionamiento: 0-40 °C (32-104 °F).
Para uso en espacios interiores solamente.
Especificaciones sujetas a cambio sin aviso debido a continuas mejoras del producto.
Z-WAVE INTEROPERABILITY
This product can be included and operated in any Z-Wave network with other Z-Wave certified
devices from other manufacturers and/or other applications. All non-battery operated nodes
within the network will act as repeaters regardless of vendor to increase reliability of the
network.
INTEROPÉRABILITÉ ENTRE LES DISPOSITIFS Z-WAVE
Ce produit peut être utilisé dans un réseau Z-Wave avec d'autres appareils certifiés Z-Wave
produits par d'autres fabricants et d'autres applications. Tous les nœuds fonctionnant sans
pile au sein du réseau joueront le rôle de répétiteurs, quel que soit le fournisseur, afin de
rehausser la fiabilité du réseau.
INTEROPERABILIDAD Z-WAVE
Este producto se puede incluir y puede funcionar en cualquier red Z-Wave con dispositivos
de otros fabricantes y otras aplicaciones que cuenten con la certificación Z-Wave. Todos
los nodos que formen parte de la red y que funcionen sin pilas actuarán de repetidores
independientemente del proveedor con el fin de aumentar la fiabilidad de la red.
NOTE: Actual performance of any CFL or LED will vary from bulb type to bulb type and among
different manufacturers. It is important to note only bulbs designed as dimmable should be used
with a dimmer. To find out if your bulb is dimmable, please check the package, the bulb itself or call
the a bulb manufacturer directly.
For a complete list of recommended CFL/LED bulbs for this and other Z-Wave products from
Honeywell, please visit www.honeywellelectricalaccessories.com.
4
CONNECTION
CONNECTING YOUR DEVICE TO A Z-WAVE NETWORK
1.
Follow the instructions for your Z-Wave certified controller to add
a device to the Z-Wave network.
2.
Once the controller is ready to add your device, press and release
the top or bottom of the wireless smart dimmer (rocker) to add it in
the network.
If prompted by the controller to enter the S2 security code, refer to the
QR code/security number on the back of the box, or the QR code label
on the product.
DSK :
XXXXX
-12565-22671
-26939-47599
-19612-25872
-47752
Now you have complete control to turn your fixture ON/OFF
according to groups, scenes, schedules and interactive automations
programmed by your controller.
If your Z-Wave certified controller features remote access, you can now
control your fixture from your mobile devices.
REMOVING AND RESETTING THE DEVICE
1.
Follow the instructions for your Z-Wave certified controller to remove a
device from the Z-Wave network.
2.
Once the controller is ready to remove your device, press and release
the top or bottom of the wireless smart dimmer (rocker) to remove it
from the network.
RETURNING DIMMER TO FACTORY DEFAULTS
Quickly press ON (top) button 3 times, then, immediately press the
OFF (bottom) button 3 times. The LED will flash 5 times when
completed successfully.
Note: This should only be used in the event your network's primary controller is missing
or otherwise inoperable.
5
CUSTOMIZATION
2.
1.
CHANGING THE COLOR OF THE PADDLE
This step is optional. Before installation, you may want to change the color of
the paddle to match your wallplate or décor.
1.
Lift the air gap tab at the base of the paddle.
2.
Push side tabs in on one side and then the other to release paddle. Lift
the cover up and off.
3.
Simply put the new paddle onto the switch by inserting the air gap and
side tabs and snapping securely into place.
Once this step has been completed, please return to Section 3.
This device supports Association Command Class (3 Groups)
• Association Group 1 supports Lifeline, Multilevel Switch Report
• Association Group 2 supports Basic Set and is controlled by pressing
the ON or OFF button with the local load
• Association Group 3 supports Basic Set and is controlled by double
pressing the ON or OFF button
• Each Association Group supports 5 total nodes