Technical Specification - Presto Compact C-DRY Guia De Instalacion

Tabla de contenido
Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 17
This product must be installed by qualified personnel.
This product must be connected using AWG12 rigid cable.
A bad connection to the ground can cause severe electrical shocks that can lead to
death.
Disconnect the power supply at the circuit breaker before installation and maintenance.
All hand-driers must be installed with a 3-core cable. The earth cable must be
connected to the back of the hand-drier.
Dimensions
152

Technical Specification

Item
Operating voltage
Hot air discharge volume
Air discharge speed
Sound Level
Thermal protection of the motor
Heating element
Heater Thermal Protection
Operation of the circuit
Sensor range
Safety time delay
Comfort time delay
Recommended installation heights
Men
Women
Children (4 – 7 years)
Children (8 – 10 years)
Children (11 – 13 years)
Children (14 – 16 years)
100
Disabled person
Performance
220-240VAC, 50/60Hz, 1.0kW
74m³/h
95-115 m/s
76.6 dB-A Max @ 1M
240VAC, Auto Resetting Thermostat turns unit off at 95°C
ON/ OFF Heating options (part no 11); Range Adjustable by
Owner, 325 - 500 W
Auto Resetting Thermostat turns heater element off at 85°C,
Resets at 75°C,Thermal cut-off at 142°C
Automatic infrared, self-adjusting
172 ±20
Automatic shut-off after continuous use: 60 s
Automatic shut-off after the hands are removed: 2 s
1270
(50")
1194
(47")
889
(35")
991
(39")
1092
(43")
1194
(47")
1016
(40")
9
Tabla de contenido
loading

Este manual también es adecuado para:

60364

Tabla de contenido