STEP 1:
Rotational adjustment of the photo control is
tool-less.
STEP 2:
Engage/install photo control into NEMA®
receptacle on top of the fixture.
STEP 3:
Firmly rotate photo-control with its photo-
eye approximately in the 'N' north direction.
Some photo-controls operate best somewhere
between NW and NE.
ELECTRICAL CONNECTIONS
STEP 1:
For 120/277/347V applications make the following Electrical Connections
to the terminal block:
a. Connect the black fixture lead to the voltage supply position of
the terminal block.
b. Connect the white fixture lead to the neutral supply position of
the terminal block.
c. Connect the green or green/yellow ground lead to the green
wire position of the terminal block.
For 208/240/480V applications, make the following Electrical Connections
to the terminal block:
a. Connect Hot 1 supply lead to the black lead.
b. Connect Hot 2 supply lead to the white lead
c. Connect the green or green/yellow ground lead to the supply
ground lead.
Dimming capabilities may be accessible through optional Nema
receptacle.
NOTE: Brown and orange leads on optional NEMA Receptacle are not
used and are capped off. No electrical connection is necessary.
d. If Dimming is an option; connect the violet dimming positive lead to
the supply dimming positive lead. If dimming is not being used ensure to cap off the violet lead.
e. If Dimming is an option; connect the grey dimming negative lead to the supply dimming negative lead. If dimming is not being used ensure to
cap off the grey lead.
f.
If dimming through Nema is an option, install photo control with dimming capabilities.
STEP 2:
Push excess supply wires into pole.
STEP 3:
Close cover re-tighten the captive D-ring, making sure that no wires are pinched and latches are fully engaged.
© 2018 Cree, Inc. All rights reserved. For informational purposes only. Content is subject to change. See
http://lighting.cree.com/warranty for warranty and specifications. Cree
Inc. NEMA
is a registered trademark of the National Electrical Manufacturers Association
®
2 of 2
DRV
CRTL
FIELD ADJUSTABLE DIMMING
(OPTIONAL)
NOTE: This luminaire may be provided with
field adjustable dimming. Luminaires leave
the factory adjusted to the maximum setting
specified when ordered. Verify which dimming
module, either Figure 3 is in the luminaire and
visit the product specification sheet for lumen
and power multipliers for each field adjustable
output dim setting.
STEP 1:
The Dimming module is located inside the
luminaire. Open the cover by loosening the
and the Cree Logo are registered trademarks of Cree,
®
captive D-ring and allow the cover to swing
open.
STEP 2:
Establish the desired input power multiplier by
referring to the product dimming spec sheet
and turn the switch to the correlating position.
For the half moon shaped dial (Figure 3) the
center of the flat side should be turned to the
desired setting.
STEP 3:
Adjust the Dimming Module, see Figure 3,
to the selected position and close the cover
ensuring no wires are pinched.
NOTE: The Utility Option will be limited to the
highest setting ordered.
TERMINAL
BLOCK
LINE
LINE-BLACK
OR HOT 1
GREEN
GROUND-GREEN
NEUTRAL
NEUTRAL-WHITE
OR HOT 2
OPTIONAL NEMA CONTENT
VIOLET
DIM (+) VIOLET
GREY
DIM (-) GREY
LUMINAIRE