10a. Settings and Capacities in liters
Coffee and Vending machines
Coffee-Espresso
°Clarke
°KH
PPM
°FH
(GB)
< 6
8
107
11
7
9
125
13
8
10
143
14
9
11
161
16
10
13
179
18
11
14
196
20
12
15
214
21
13
16
232
23
14
18
250
25
15
19
268
27
16
20
286
29
17
21
304
30
19
24
339
34
21
26
375
38
23
29
411
41
26
33
464
46
29
36
518
52
33
41
589
59
38
48
679
68
The COFFEE-ESPRESSO application describes the production of hot drinks with
steam operation. The stated capacities are intended as guidelines for single cup
dispense. The capacities may vary according to dispensed volume and machine
type. Please contact us for recommendations.
Combi Steamers / Self-Cooking Systems / Steam Cookers / Ovens
Direct Injection
°Clarke
°KH
PPM
°FH
(GB)
< 6
8
107
11
7
9
125
13
8
10
143
14
9
11
161
16
10
13
179
18
11
14
196
20
12
15
214
21
13
16
232
23
14
18
250
25
15
19
268
27
16
20
286
29
17
21
304
30
19
24
339
34
21
26
375
38
23
29
411
41
26
33
464
46
29
36
518
52
33
41
589
59
38
48
679
68
Capacities are intended as guidelines and can vary according the machine typ.
Please contact us for recommendations.
By-
capacity in liters
pass-
S
M
L
levels
5
3'000
5'000
9'200
5
2'570
4'280
7'890
4
1'870
3'120
5'750
4
1'670
2'780
5'110
4
1'500
2'500
4'600
4
1'360
2'270
4'180
3
1'070
1'790
3'290
3
990
1'650
3'030
3
920
1'530
2'820
3
860
1'430
2'630
3
800
1'340
2'470
3
760
1'260
2'320
3
680
1'130
2'070
2
540
890
1'640
2
490
810
1'500
2
430
720
1'330
2
390
650
1'190
2
340
570
1'040
2
300
490
910
By-
capacity in liters
pass-
S
M
L
levels
0
1'500
2'500
4'660
0
1'290
2'140
4'000
0
1'130
1'880
3'500
0
1'000
1'670
3'110
0
900
1'500
2'800
0
820
1'360
2'550
0
750
1'250
2'330
0
690
1'150
2'150
0
640
1'070
2'000
0
600
1'000
1'870
0
560
940
1'750
0
530
880
1'650
0
470
790
1'470
0
430
710
1'330
0
390
650
1'220
0
350
580
1'070
0
310
520
960
0
270
450
850
0
240
390
730
Vending
°Clarke
°KH
PPM
(GB)
XL
13'200
< 6
8
107
11'310
7
9
125
8'250
8
10
143
7'330
9
11
161
6'600
10
13
179
6'000
11
14
196
4'710
12
15
214
4'350
13
16
232
4'040
14
18
250
3'770
15
19
268
3'540
16
20
286
3'330
17
21
304
2'980
19
24
339
2'360
21
26
375
2'150
23
29
411
1'900
26
33
464
1'710
29
36
518
1'500
33
41
589
1'300
38
48
679
The VENDING application describes the production of hot drinks without steam
operation. The stated capacities are intended as guidelines for single cup
dispense. The capacities may vary according to dispensed volume and machine
type. Please contact us for recommendations.
Boiler System
°Clarke
°KH
PPM
(GB)
XL
6'670
< 6
8
107
5'710
7
9
125
5'000
8
10
143
4'440
9
11
161
4'000
10
13
179
3'640
11
14
196
3'330
12
15
214
3'080
13
16
232
2'860
14
18
250
2'670
15
19
268
2'500
16
20
286
2'350
17
21
304
2'100
19
24
339
1'900
21
26
375
1'740
23
29
411
1'540
26
33
464
1'380
29
36
518
1'210
33
41
589
1'050
38
48
679
Capacities are intended as guidelines and can vary according the machine typ.
Please contact us for recommendations.
13
By-
capacity in liters
°FH
pass-
S
M
levels
11
6
3'540
6'250
13
6
3'040
5'360
14
5
2'120
3'750
16
5
1'890
3'330
18
5
1'700
3'000
20
5
1'550
2'730
21
4
1'180
2'080
23
4
1'090
1'920
25
4
1'010
1'790
27
4
940
1'670
29
4
880
1'560
30
4
830
1'470
34
4
750
1'320
38
3
580
1'020
41
3
530
930
46
3
470
820
52
3
420
740
59
3
370
650
68
3
320
560
By-
capacity in liters
°FH
pass-
S
M
levels
11
3
2'140
3'570
13
3
1'840
3'060
14
2
1'410
2'340
16
2
1'250
2'080
18
2
1'130
1'880
20
2
1'020
1'700
21
2
940
1'560
23
2
870
1'440
25
2
800
1'340
27
2
750
1'250
29
2
700
1'170
30
2
660
1'100
34
2
590
990
38
1
480
790
41
1
430
720
46
1
380
640
52
1
340
570
59
1
300
510
68
1
260
440
L
XL
11'670
16'670
10'000
14'280
7'000
10'000
6'220
8'890
5'600
8'000
5'090
7'270
3'890
5'550
3'590
5'130
3'330
4'760
3'110
4'440
2'920
4'170
2'750
3'920
2'460
3'510
1'900
2'720
1'740
2'480
1'540
2'200
1'380
1'970
1'210
1'730
1'050
1'310
L
XL
6'670
9'520
5'710
8'160
4'370
6'250
3'890
5'550
3'500
5'000
3'180
4'550
2'920
4'170
2'690
3'850
2'500
3'570
2'330
3'330
2'190
3'120
2'060
2'940
1'840
2'630
1'480
2'120
1'350
1'930
1'200
1'710
1'070
1'530
940
1'340
820
1'170