!
WARNING Before using this outdoor fire table, make sure you have read, understand and
are following all information provided in the important Safety Information section of this
manual. Failure to follow those instructions can cause death, serious injury or property damage.
13. CHECKING FOR LEAKS
Make a leak check solution by mixing 1 part dishwashing soap
with 3 parts water in a spray bottle.
Make sure the control knob is "OFF. " Then, turn the Natural Gas on
at its source.
Spray leak solution on the valve connections, paying particular
attention to the areas indicated by the arrows.
If any bubbles appear turn the Natural Gas o at its source, recon-
nect and re-test. If you continue to see bubbles after several
attempts, disconnect the Natural Gas Source and Contact Real
Flame ® at 1-800-654-1704 for assistance.
If no bubbles appear after one minute turn the gas
source "OFF", wipe away solution and proceed.
NOTE: The proper manifold pressure for this converted appliance is 7" water column.
NOTE: The maximum inlet gas pressure for this unit is 10.5 in wc (2.61 kPa)
The minimum inlet gas pressure for this unit is 3.5 in wc (0.87 kPa)
14.)
Cut the existing French Plaque o of the control panel using wire cutters. Re-attach
French plaque and NG conversion plaque included with this kit to the fire table using
the included cable kit.
Cut Cable
NATURAL GAS CONVERSION
Check for leaks at these locations
Re-attach both plaques
8