Safety Features; Helpful Information - ProBreeze PB-AC01 Manual De Instrucciones

Ocultar thumbs Ver también para PB-AC01:
Tabla de contenido
Idiomas disponibles
  • ES

Idiomas disponibles

Safety Features

Anti-Frost Protection
If the compressor operates continuously for
more than 10 minutes and the internal pipe
temperature drops to below 0°C for more than
20 seconds the compressor and water spraying
motor will turn off. The display will show E4 and
the appliance will initiate anti-frost protection
rendering the control panel buttons inactive
apart from the power button. Once the internal
pipe temperature exceeds 8°C the anti-frost
protection will cease and the appliance will
return to operating at the chosen settings.

Helpful Information

Issue
The air-conditioner
is not operating.
Poor cooling.
15 | English
Compressor Delay Protection
To protect the compressor, apart from when the
appliance and compressor are activated for the
first time after being turned on via the power
button, there will be a three minute delay
between every occurrence of the compressor
turning off and on.
Cause
No power.
Water tank full.
Room temperature too low.
Room temperature lower than the
set temperature cooling mode.
There is direct sunlight.
Doors and windows are open or
there are other heat sources.
Dirty filters.
Air inlet or air outlet clogged.
Appliance not on a flat surface.
Resolution
Connect the unit to a live
power socket and turn it on.
Drain the water stored in the unit.
It is recommended that this
unit be operated at 5-32°C.
Increase the set temperature
above the room temperature.
Draw curtains.
Close doors and windows and
remove other heat sources.
Clean filters.
Remove the obstruction.
Place the appliance on a flat surface.
Tabla de contenido
loading

Tabla de contenido