GB
D
Assembly steps
Install the profile seal and
overflow unit. Screw the
fastening flange with O-ring
into the overflow unit.
Mount flexible drain pipe. The
drain pipe can be mounted
alternatively in 40/50 mm to
the drain system.
Srew in threaded valve with
sealing element into the drain
body.
Applies only for model
791235 00 0 00 1000.
Attach overflow pipe tube
under the bath tub.
Screw the outer ring of inlet-
element onto the srew-top of
threaded valve.
Screw into the thread
manually.
Install the screw connection
piece.
To open the valve cone:
22
Turn the rotatable collar
clockwise.
E
Cleaning
Turn off cover plate by hand.
Clean inlet-element under
flowing water.
Replace damaged seal.
The assembly takes place in reverse order!
560422_Duravit.indd 12
Tighten the fastening flange.
Insert the seal into the drain
hole.
Tension the threaded valve
with assembly help.
Install the overflow pipe and
make certain it is inserted far
enough.
Lightly tighten the hexagon
socket head screw.
Insert the rotatable collar into
the overflow unit.
Install the connecting bend
to the drain and tighten the
union nut manually.
After assembly is complete,
23
perform a leakage test.
Remove cover.
Loosen internal poly angular
wrench at the valve cone.
Clean drain body on request.
12
Dispose drain elbow.
Mounting arrangement with
a plastic tub (threaded valve
30 mm).
Cut the overflow pipe off to
a suitable length.
Insert inletelement.
Place the cover plate directly
on the thread.
Loosen the connecting bend
from the drain and connect
on the water side.
To close the valve cone:
21
Turn the rotatable collar
anticlockwise.
Loosen internalpoly angular
screw and remove inlet-
element.
Close valve and hold this
position with the operating
handle. Remove valve cone.
27.11.2013 09:40:02