XD10TTAM
9. Golden Rules When Using Lens 3
GOLDEN RULES WHEN USING LENS 3
RINS1513-1
1) Installation height must not be
less than 1.5m.
2) Set the Microwave to the
shown position.
MW RANGE ADJUST
MW RANGE ADJUST
10m
1m
3) Set Dip switch 5 to 'High
Sensitivity'.
4) If used, set the Anti-Mask range
no more than approximately 30cm.
AM ADJUST
AM ADJUST
30cm approx
0m