UV100A ULTRAVIOLET SYSTEMS
CAUTION
Breakable Glass Hazard.
Can cause personal injury.
Be careful when inserting bulb(s) into lamp base.
Wear protective gloves when handling bulb(s).
MERCURY NOTICE
This device contains mercury in the sealed
ultraviolet bulb(s). Do not place your used bulb(s) in
the trash. Dispose of properly.
Broken Bulb Cleanup.
Do not use a household vacuum.
Sweep debris into a plastic bag and dispose of
properly.
Contact your local waste management authority for
instructions regarding recycling and the proper
disposal of old bulb(s).
11. Insert the bulb into the base unit with the lamp light
indicator at the eleven o'clock position (left of the
raised button on the unit cover). See Fig. 5. If you
touch the lamp glass with your hands, use a cloth to
wipe fingerprints from the glass. See Fig. 6.
Fig. 5. Insert bulb into base unit.
Fig. 6. Use cloth to wipe fingerprints from glass.
12. Continue lightly pushing in on the lamp handle while
rotating it slowly counterclockwise. This should cause
the lamp handle to drop into the bottom of the lamp
well.
68-0248ES—01
13. Rotate the lamp handle clockwise until it snaps into
place with the lamp indicator light aligned with the
raised button on the unit cover. See Fig. 7.
14. Plug the cord into the nearby 120 or 240 Vac
electrical outlet.
15. Reconnect the power to the HVAC system.
16. Choose a location on the adjacent HVAC equipment
for the HVAC maintenance label included in the air
M22847
treatment system packing box. Choose a location
that a future installer can easily see during any future
HVAC maintenance or repair.
17. Adhere the HVAC maintenance safety label to the
HVAC equipment (selected in step 16) such as the
furnace, air cleaner or humidifier. See Fig. 8.
M22843
8
Fig. 7. Snap lamp into place.
WARNING
UV Light Hazard.
Harmful to bare skin and eyes.
Can cause temporary or permanent loss of vision.
Never look at lamp while illuminated.
View illumination only through light indicator
located on lamp handle.
To prevent exposure to ultraviolet light, disconnect
power to ultraviolet system before servicing any
part of heating and air conditioning system.
Fig. 8. HVAC maintenance UV safety label.
M22849
M22868