Connecting To The Pc And Powering Up; Operation In The Eu - Cambium Networks PTP 550 Serie Guia De Inicio Rapido

Tabla de contenido
Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 55

Connecting to the PC and powering up

1
Check that the ODU ETH port is connected to the Ethernet + Power port of the power supply.
2
Connect the PC Ethernet port to the LAN port of the PSU using a standard (not crossed)
Ethernet cable.
3
Apply mains or battery power to the PSU. The green Power LED should illuminate continuously.
4
Check that the ODU red Ethernet LED illuminates continuously.
5
Open a web browser and type: 169.254.1.1
When prompted, enter admin/admin to login to the GUI and complete the configuration.
Conforming to the limits
Ensure the link is configured to conform to local regulatory requirements by configuring the Country
parameter (located in the web management interface at Configuration > Radio > General). When using
connectorized ODUs with external antennas, also ensure that the antenna gain is configured correctly in
the ODU (the Antenna Gain parameter is located in the web management interface at Configuration >
Radio > Power Control).

Operation in the EU

Frequency Bands, Maximum Operating Power, Safe distance
In the EU, the 5 GHz PTP 550 products operate in the following frequency bands up to the maximum
power shown:
Operating
Frequency Band
Standard
5470 – 5725 MHz
EN 301 893
5725 – 5875 MHz
EN 302 502
Note 1:
Operation in the 5.8 GHz band is not permitted in the following European countries: AT,
BG, CZ, CY, FR, HR, IT, LU, LV, NL, PL, TR. In other countries, government licenses may be
required to allow operation, please check your national government website.
Note 2:
The radio applies national frequency allocations, power and DFS settings for each country
code.
Note 3:
In the UK and Ireland, light licensing applies. Obtain a license from your government web-
site.
Note 4:
For Norway, use of the 5725–5795 MHz and 5815–5850 MHz frequency bands is
authorized.
Note 5:
5725 – 5875 MHz operation is enabled by downloading and applying a license key from the
Cambium web-site.
For PTP 550 products deployed in the EU, the minimum safe distance between the equipment and
humans is 10 cm.
Restrictions & requirements for authorization for use
This equipment is for outdoor use only.
EU
Maximum Power
Limit (EIRP)
1 Watt / 30 dBm
4 Watts / 36 dBm
Permitted usage
Available for general usage
within all EU nations
Permitted in some EU
nations, see notes 1 - 5
PAGE 10
PTP 550 QUICK START GUIDE
5 GHz units that
support this frequency
band
All PTP 550
All PTP 550