Página 1
A401 INSTRUCTION MANUAL We’ll Make It Stress-Free If you have any questions along the way, just give us a call. 1-800-359-5520. We’re ready to help! Scan for more information san.us/454...
Página 2
IMPORTANT SAFETY INSTRUCTIONS – SAVE THESE INSTRUCTIONS – PLEASE READ ENTIRE MANUAL PRIOR TO USE Before getting started, let’s make sure this product is perfect for you! Does your AV component system weigh more than 15 lb (6.8 kg) including accessories? No —...
Página 4
Supplied Parts and Hardware WARNING: This product contains small items that could be a choking hazard if swallowed. Before starting assembly, verify all parts are included and undamaged. If any parts are missing or damaged, do not return the damaged item to your dealer;...
Página 5
Additional Parts and Hardware STEP 3 Parts and Hardware Glass Shelf Safety Plate Allen Key Screws M5 x 20 M5 x 6...
Página 6
STEP 1 Determine Configuration Determine whether to use the single-shelf configuration or the stacked configuration based on the height of the A401 and where you choose to install the mount. 1.34 14.50 33.9 368.3 18.00 457.2 POST INSTALLMENT 1" HEIGHT ADJUST POST INSTALLMENT ROLL 7.5...
Página 7
IMPORTANT: For stacking configurations, stack from the top down. 1.34 33.9 14.50 368.3 5.31 18.00 457.2 POST INSTALLMENT 1" HEIGHT ADJUST POST INSTALLMENT ROLL 7.5 6.11 6.55 155.1 166.3...
Página 8
STEP 2 Attach Wall Plate Wood Stud Option CAUTION: Avoid potential personal injuries and property damage! ● Drywall covering the wall must not exceed 16 mm (5/8 in.) ● Minimum wood stud size: common 51 x 102 mm (2 x 4 in.) nominal 38 x 89 mm (1 1/2 x 3 1/2 in.) Locate your stud.
Página 9
Drill pilot holes using a 3 mm (1/8 in.) diameter drill bit. IMPORTANT: Be sure to drill into the center of the stud. IMPORTANT: Pilot holes must be drilled to a depth of 63.5 mm (2½ in.). Install the wall plate using the lag bolt and the washer .
Página 10
STEP 2 Attach Wall Plate Solid Concrete or Concrete Block Option CAUTION: Avoid potential personal injuries and property damage! ● Mount the wall plate directly onto the concrete surface ● Minimum solid concrete thickness: 203 mm (8 in.) ● Minimum concrete block size: 203 x 203 x 406 mm (8 x 8 x 16 in.) Remove the front and top covers from the wall plate...
Página 11
Insert concrete anchors CAUTION: Be sure the anchors are seated flush with the concrete surface. Install the wall plate using the lag bolt the washer and the anchor as illustrated. Secure the bottom of the wall plate using the #8 screw and anchor Tighten the lag bolt only until it is pulled firmly against the washer.
Página 12
STEP 2 Attach Wall Plate Drywall Option CAUTION: Avoid potential personal injuries and property damage! ● Mount the wall plate directly onto the wall ● Drywall covering the wall must be at least 13 mm (1/2 in.) ● Do not install anchors into the seam between drywall pieces Remove the front and top covers from the wall plate...
Página 13
Remove the wall plate template and insert anchors CAUTION: Be sure the anchors are seated flush with the concrete surface. Install the wall plate using the #8 screw . Insert the screw through the wall plate and into the anchors. Tighten the screw only until it is pulled firmly against the wall plate.
Página 14
STEP 3 Attach Glass to Wall Plate Slide the glass shelf into the wall plate . Line up the holes in the shelf to the holes in the wall plate. Secure the glass shelf to the wall plate using screws Attach the safety plate to the glass shelf using screws...
Página 15
Manage Cables - Single Shelf Configurations Cables can be routed through the opening in the lower back of the wall plate.
Página 16
Manage Cables - Stacked Shelf Configurations Cables can be routed through the inside of the wall plates for stacked confi gurations.
Página 17
Adjustments Adjust the height using the allen key. Adjust level by hand. Tighten using the allen key. Reattach top and front covers.
Features and Benefits Can be mounted to drywall, wood stud, or concrete Level can be adjusted by±7.5° post-installation Height can be adjusted by 1 in. post installation Is stackable to accommodate multiple components (not to exceed 15 lb (6.8 kg) on each shelf)
Página 20
ESPAÑOL INSTRUCCIONES DE SEGURIDAD IMPORTANTES. CONSÉRVELAS. LEA TODO EL MANUAL ANTES DE UTILIZAR ESTE PRODUCTO. Antes de comenzar, verifiquemos que este producto sea el ideal para sus necesidades. Ver página 2 1. ¿Su sistema de componentes AV pesa más de 6.8 kg (15 libras) incluyendo los accesorios? No —...
Página 21
ESPAÑOL PASO 2 Fijar la placa mural Opción para montantes de madera Ver página 10 PRECAUCIÓN: Evite lesiones y daños materiales. ● El yeso que recubre la pared no debe exceder los 16 mm (5/8''). ● Tamaño mínimo del montante de madera: común 51 mm x 102 mm (2" x 4") (nominal 38 mm x 89 mm /1 1/2 x 3 1/2 "). Localice los montantes.
Página 22
ESPAÑOL Opción para bloque de hormigón (Cont.) Ver página 11 PRECAUCIÓN: Insertar los anclajes de hormigón Cerciórese de que los anclajes queden nivelados respecto de la superficie de hormigón. Instale la placa mural usando los tornillos tirafondo y las arandelas Ajuste los tornillos tirafondo y las arandelas solo hasta que PRECAUCIÓN: queden firmes contra la placa mural.
La nivelación se puede ajustar en hasta ±7,5° después de la instalación. La altura se puede ajustar en hasta 1" después de la instalación. El estante A401 es apilable a fin de alojar múltiples equipos (peso máximo admitido por estante: 6.8 kg o 15 lb).
Página 24
Thank you for choosing Sanus Accents! Please take a moment to let us know how we did: Call us: 1-800-359-5520 Email us: [email protected] Leave a review: accents.sanus.com Milestone AV Technologies and its affi liated corporations and subsidiaries (collectively, “Milestone”), intend to make this manual accurate and complete. However, Milestone makes no claim that the information contained herein covers all details, conditions, or variations.