6. Menu Instruction
When the temperature is displayed in Centigrade
Menu
code
Temperature Set
TS
Heating Differential
HD
Cooling Differential
CD
Alarm High Limit
AH
Alarm Low Limit
AL
PT
Compressor Delay
Temperature
CA
Calibration
Display in Fahrenheit
CF
or Centigrade
When the temperature is displayed in Fahrenheit
Menu
code
Temperature Set
TS
Heating Differential
HD
Cooling Differential
CD
Alarm High Limit
AH
Alarm Low Limit
AL
PT
Compressor Delay
Temperature
CA
Calibration
Display in Fahrenheit
CF
or Centigrade
6.1 Temperature Control Range Setting (TS, HD, CD)
When the controller is working normally, the LED displays
current measured temperature, and automatically identify
and switch refrigeration and heating working modes.
Function
Value
Value
Value
Function
Value
Value
Value
Setting range
-50~120°C
0.3~15°C
0.3~15°C
-50~120°C
-50~120°C
0~10 minutes
-15°C~15°C
Setting range
-50~248°F
1~30°F
1~30°F
-50~248°F
-50~248°F
0~10 minutes
-15°F~15°F
5
Default
Remarks
setting
25°C
2.0°C
6.1
2.0°C
90°C
6.2
-40°C
0
6.3
6.4
0°C
C
6.5
Default
setting Remarks
77°F
3°F
6.1
3°F
200°F
6.2
-40°F
0
6.3
6.4
0°F
6.5
F