KEY
1. Control Panel
2. Motion Sensor
1
3. Front Access Panel
4. Access Panel Latch
5. Certified Filter Sticker
2
6. Hybrid Filter
3
7. Cord Management
8. Power Switch
9. Power Cord Socket
10. IEC Plug
SET UP - Reference KEY section
1. Open unit by pressing the access panel latch (4) down while pulling the front access panel towards you.
2. Remove bag from filter and place back in unit.
3. Plug the IEC plug (10) into the power cord socket (9) on the back of the unit.
MOUNTING MAIN ASSEMBLY
1. Choose an area to mount the unit near a standard outlet receptacle (Cord length approximately 1.6 meters).
2. Mark the wall with the two top mounting locations. If mounting location is over an existing stud, no preparation
needed. If mounting location is over drywall only or other surface requiring additional support, use anchors.
3. [Anchor use only] To use anchors, drill a 9.5mm hole in the mounting hole location(s) and install anchors into wall.
4. Install screws leaving approximately 1/4" (6mm) from the head of the screw to the wall. Do not install screws
all the way.
5. Hang the unit on the screws installed in previous step using the top key-hole mounting holes.
6. Open the front door of the unit and mark the locations of the mounting holes at the bottom of the unit on
the wall.
7. [Anchor use only] Remove the unit from the wall and install anchors in marked location(s)
8. Hang the unit back on the wall, and tighten the two screws in the top mounting locations.
9. Place the (2) provided stickers over the top mounting hole locations to maximize performance.
10. Install screws into the bottom mounting locations.
11. Remove the filter(s) from their packaging and install them in the unit Note: The "AeraMax Pro Certified Filter
Sticker" on the filter must align with the identical sticker found on the unit. If the filter is not installed properly,
the unit will not power on.
12. Plug the power cord into standard outlet receptacle.
13. Reach behind the unit on the back bottom right to access the power switch and turn unit on.
Note: Manual mode will not be available for 1 minute upon initial power-up.
6
4
6
5
Back of Unit
7
8
9
10
4 Mounting Locations
CARE AND MAINTENANCE
CLEANING:
• Clean external housing as necessary by wiping with a dry, soft cloth; for stains, use a warm, damp cloth.
• Do not use volatile fluids such as benzene, paint thinner, scouring powder or other cleaners that may damage the unit surface.
• Clean intake and exhaust vents by wiping with a dry, soft cloth.
FILTER REPLACEMENT:
The replacement filter indicators will signal when to replace the HEPA Filter and/or Carbon filters. The replacement period will vary depending on
the hours of use, air quality, and rate of air flow. However, under normal usage, most HEPA Filters need to be replaced every 1 year, and Carbon
filter every 6 months. When a filter needs to be replaced the following color will be shown on any one of the HEPA or CARBON filter replacement
indicators:
Amber flashing = 90% filter wear (recommendation to order new filters)
Red = 100% filter wear (replace with new filters)
Do not wash and reuse any of the filters – they will not work effectively. Only use AeraMax
using any other replacements.
FILTER REPLACEMENT PROCEDURE:
1
2
Press the access panel latch down while
pulling front panel towards you.
FILTER LIGHT RESET:
When installing a new filter the unit will automatically detect the filter type but the user will have to manually reset the filter replacement indicators. To reset any
of the filter replacement indicators, press and hold filter type button that was replaced (HEPA or Carbon) until the light turns off. Repeat for other filter types as
needed. When replacing the hybrid filter, reset both the HEPA and carbon indicator lights.
TROUBLESHOOTING
PROBLEM:
POSSIBLE SOLUTION:
The air quality control system fails to start.
• Check to assure unit is connected to power supply.
• Make sure filters are genuine AeraMax
brands. IMPORTANT: Make sure to align the AeraMax PRO Certified Stickers on the filter
and the inside of the unit. The arrows should point towards the back of the unit.
• Review Filter Replacement Method section for further detail.
• Make sure front access panel is closed completely.
• Make sure power switch is on.
The unit makes a faint ticking sound.
• This indicates that the "PlasmaTRUE™" bipolar ionizer is working.
The HEPA and/or Carbon Filter replacement indicator light
• Repeat filter light reset instruction.
remain lit after replacing the filter(s).
PRO brand replacement filters as units will not function
®
3
Remove old filter(s).
When inserting new filters, be sure to remove
the plastic bag. When inserting new Hybrid
or HEPA filters, align the AeraMax
Certified Filter stickers on the filter and the
inside of the unit. The arrow should point
towards the back of the unit.
Reference (5) on the KEY section.
®
PRO filters, as unit will not function with other
®
PRO
7