TROUBLESHOOTING
To test the detection coverage:
During the TEST mode, the controlled load turns ON for 5 seconds each time the
sensor detects occupancy.
1. Press and hold the ON/OFF button. After 10 seconds the nightlight flashes.
The load turns ON if it was not already ON. The sensor is now in a TEST mode
that lasts 5 minutes. (You can end the TEST mode sooner by pressing the ON/
OFF button for another 10 seconds).
2. Move out of the coverage area or stand very still. The controlled load turns
OFF after 5 seconds, if no motion is detected.
3. Move in the coverage area. The nightlight flashes each time the sensor
detects motion and the controlled load turns ON for 5 seconds.
After 5 seconds expire without motion detection, the load turns OFF.
The load turns ON automatically with the next motion detection and stays on
for 5 seconds.
4. Repeat as necessary to ensure that the desired coverage areas are within
detection range.
Load will not turn ON (nightlight is visible):
Press ON/OFF button. The load should turn ON. If not:
• Check the light bulb and/or motor switch on the fan mechanism.
• Turn off power to the circuit then check wire connections.
Load will not turn ON (nightlight is NOT visible):
• Check the light bulb and/or motor switch on the fan mechanism.
• Make certain that the circuit breaker is on and functioning.
• Turn off power to the circuit then check wire connections.
• Call 888.817.0571 for technical support.
Load will not turn OFF:
• Make sure no motion is occurring in the coverage area until the 30 minute
time delay expires.
• Hot air currents and heat radiating devices can cause false detection. Make
sure the sensor is at least 6 feet (2 meters) away from devices that are a
significant heat source (e.g., heater, heater vent, high wattage light bulb).
• Press the ON/OFF button. If load does not turn off, turn off power to the circuit
then check wire connections.

COVER PLATES

WattStopper RS wall switches fit behind industry standard decorator style switch
cover plates.

WARRANTY INFORMATION

WattStopper warranties its products to be free of defects in materials
and workmanship for a period of five (5) years. There are no obligations
or liabilities on the part of WattStopper for consequential damages
arising out of, or in connection with, the use or performance of this
product or other indirect damages with respect to loss of property,
revenue or profit, or cost of removal, installation or reinstallation.
2800 De La Cruz Boulevard, Santa Clara, CA 95050
800.879.8585 • www.wattstopper.com
06015r4 3/2013
Please
Recycle
Tabla de contenido
loading

Tabla de contenido