Gerreka NAOS Guía Rápida De Instalación Y Programación página 14

Tabla de contenido
Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 1
2
STEP
Store door
closed
position
3
STEP
Learn forces
(opening
and closing)
4
STEP
Opening
sensitivity
5
STEP
Closing
sensitivity
6
STEP
Type of
radio (fixed
or roller
code)
7
STEP
Semi-auto
or auto
closing and
standby
time
14
Press SET to save the position
Press SET to open the door
When it has closed,
press SET to save
In steps 4 to 12, programming can be finished
early by keeping SET pressed down.
Press SET to confirm
Press SET to confirm
Press SET to confirm
Press SET to confirm
Close the door through to the
closing stopper using |+ / |-
When it stops, press SET to
confirm.
Press SET again to close.
Select the value by pressing |+ / |- :
1: maximum sensitivity;
...;
6: minimum
Select the value by pressing |+ / |- :
1: maximum sensitivity;
...;
6: minimum
Press |+ / |- to select fixed code (F)
or roller code (r). The code can be
personalised by enabling the
transmitter seed (bridge or button)
of the personalised transmitter
whilst r is flashing. The display will
show r. The memory must be
empty in order to change from r to
F or from r to r..
Select mode and standby time by
pressing |+ / |- :
00: semi-auto;
01: auto, 1s; ...;
30: auto, 30s;
1.0: auto, 1 min;
1.1: auto, 1 min 10s;
4.0: auto, 4 min