To use a remote control, it is first necessary to store its code in memory. The memorisation procedure
is described hereunder. The device is able to store up to 64 different codes in memory.
By pressing P1, the control unit enters the radio learning phase: DL1 red LED flashes 1 time per
second, awaiting the key to the matched to the Step-by-Step/OPEN function (see DIP6);
When the key is stored in memory, exit from the programming mode;
By pressing P1 twice, the control unit enters the radio learning phase: DL1 red LED flashes 2 time per
second, awaiting the key to the matched to the CLOSE function;
When the key to be matched is memorised, exit from the programming mode.
If the programming mode must be left without storing any remote control signal, press P1 key until
DL1 red LED starts to flash in "power on" mode (see LED diagnostics on page 7).
To reset the memory of the receiver, press and keep P1 and P2 keys pressed for around 10 seconds
(during this period of time, both DL1 and DL2 flash rapidly).
After 10 seconds, when the two LEDs are switched on with fixed light, release the push-buttons.
When the LEDs switch back again to the original configuration, the control unit has completed the
memory reset.
NOTE:
The transmitters are memorised on an EPROM memory (U2), which can be extracted from the control
unit and inserted in a new CELL.P control unit should a replacement is required.
For safety reasons, the transmitters can be stored in memory during the opening/closing of the
motor.
The red LED indicates the activation of inputs according to the legend hereunder:
STOP
on with fixed light
DAS/PHOT
rapid flashing
SWO
1 flash with 2-second interval
SWC
2 flashes with 2-second interval
OPEN+CLOSE
3 flashes with 2-second interval
By flashing slowly, the red LED also indicates that the unit is powered.
The green LED indicates the movement direction of the motor and the status of the gate according
to the legend hereunder:
OPENING
CLOSING
Open gate without TCA
SPECIFICATIONS
Mains power supply
Output, Motor
Motor maximum power
Output, power supply of accessories
Protection level
Operating temperature
Radio receiver
No. of codes storable in memory

LED DIAGNOSTICS

1 flash with 1-second interval
2 flashes with 1-second interval
on with fixed light
230 Vac 50/60 Hz
1 motor, 230 VAC
1000 W
24Vdc 300mA max.
IP50
-20°C / +50°C
433.92 MHz, incorporated and configurable
(rolling-code or fixed+rolling-code+ ARC Advan-
ced Rolling Code)
64