Specification
Input
Sensor
specification
Sensitive distance
Flushing
procedure
Deodorizer flush
Main Flush volume
Working temperature
Product size
Product weight
Troubleshooting
Symptom
No response
(The indicator not on)
No flushing
There is response
(The indicator flickers)
No flushing or bad flushing result
Not enough water
No flushing and the LED indicator
is always on
Other
DC 6V
Type
Reflective infrared sensor
Adjustable 30-70cm (Use white card)
Flushing mode
Intensive and water saving
Manual flush
Control water supply and stop water supply within 5 minute manually.
Deodorizer flush should be activated one time under 3 users used in
consecutive 2 minutes.
Self-cleaning will be implemented once this product is not used during 24
Self-cleaning
hours.
3.5L (+/-0.5) (Dynamic pressure is 0.2Mpa(2bar))
1~55°C
120×120×8mm
140g(±5g)
1. No batteries or wrongly installed(DC type)
2. A/C power source outage or power cut(AC type)
3. There are sundries in front of a sensor The
sensor window is dirty.
4. The wire connection is not good or wrongly
connected.
1. The installation is just finished.
2. The inlet valve is not fully opened.
1. The inlet valve is not opened.
2. The filter is blocked.
3. The water pressure is too low.
The batteries are run out(DC type).
Please contact with the dealer for further service.
Probable Cause
5
Action
1. Check the batteries
2. Check the power source
3. Check the sundries
4. Check the sensor window
5. Check the wire connector
1. Wait for 60 seconds
2. Fully open the inlet valve
1. Fully open the inlet valve.
2. Clean the filter
3. Contact the water supplier
Change the batteries