LED indications on the frontal panel
Red LED
Rapid flashing
Slow flashing
Steady ON
Behaviour due to fault or defect
Any defect causing the LED to flash rapidly, takes the output into fault condition, i.e. to the
Over-Range value (2.5 % or 5 % according to the setting of the DIP-switches). For direct
scales, the output takes on the Over-Range value corresponding to the maximum value,
whereas, for the inverse scales (20..0 mA / 20...4 mA) it takes on the value corresponding
to minimum value. If slow flashing occurs, the output remains on zero.
The acceptability of the input is obviously determined by the physical full scale for the
selected scale.
Disposal of Electrical & Electronic Equipment (Applicable throughout the European Union and other
European countries with separate collection programs)
This symbol, found on your product or on its packaging, indicates that this product should not be treated as
household waste when you wish to dispose of it. Instead, it should be handed over to an applicable
collection point for the recycling of electrical and electronic equipment. By ensuring this product is
disposed of correctly, you will help prevent potential negative consequences to the environment and
human health, which could otherwise be caused by inappropriate disposal of this product. The recycling of
materials will help to conserve natural resources. For more detailed information about the recycling of this
product, please contact your local city office, waste disposal service or thè retail store where you
purchased this product.
This document is property of SENECA srl. Duplication and reprodution are forbidden, if not authorized. Contents of the
present documentation refers to products and technologies described in it. All technical data contained in the document
may be modified without prior notice Content of this documentation is subject to periodical revision.
Meaning
Internal fault: power supply, offset or reference off limit, input
acceptability exceeded. Internal error. Input overloaded. Release of
shunt (if enabled.)
Function for detecting the disconnection of the shunt required for an
input capacity, for which it is not available (M1).
Output limiting in progress (overcoming of the set over-range).