ESPECIFICACIONES DE INSTALACIÓN
Drawing Title: LS-B-127-XXXX-02
INSTALACIÓN (TÍPICA) DE LA PLACA DE SUJECIÓN
**CLAMP PLATE INSTALLATION FOR PINS ≤ ⌀0.25 [7.0]; PINS >⌀0.25 [7.0] USE HEAD-TO-HEAD INSTALLATION ON SHEET LS-B-127-XXXX-04 & -05.**
A
NOTES:
1.
CLAMP PLATE APPLICATIONS REQUIRE GUIDED EJECTION
2.
EJECTOR AND TRANSFER PIN CONCENTRICITY MUST BE WITHIN
0.030" [0.76] OR 10% OF EJECTOR PIN DIA, WHICHEVER IS
SMALLER.
3.
ENCLOSED EJECTOR BOX SUGGESTED.
4.
DO NOT SCALE PRINT
5.
BREAK ALL SHARP EDGES, 0.005 [0.03] R MAX
6.
DIMENSIONS IN INCHES [MM], UNLESS NOTED
7.
TOLERANCES UNLESS SPECIFIED:
XXX = 0.003 [0.08]
XX = 0.01 [0.3]
ANGLES = 3 30
10
RJG, Inc.
LS-B-127-XXXX Single-Channel Sensor Installation—Clamp Plate Installation
A
SECTION A-A
SCALE 1 : 2
Top of Mold
LS-B-127-XXX Electronics Housing
RJG, Inc.
3111 Park Drive
231-947-3111
www.rjginc.com
Sensores Botón Strain Gage Lynx ™ LS‑B‑127‑50/125/500/2000 | Manual del Producto
Description: LS-B-127-XXXX
Sensor Installation
Drawn: K.J.Brettschneider
Design:
Check: M.Groleau
Date: 07.21.2020