Output A conditions in monostable mode
(activation time from 01 s to 99 s)
Three different conditions are envisaged:
a) Day/Night function terminals open
Output A is activated for the programmed time only after
code "A" has been correctly entered
b) Day/Night function terminals closed
Output A is activated for the programmed time after code
"A" has been correctly entered or just by pressing key
.
c) Door lock key of inside station
Output A is activated for the time the door pressed lock
key of the inside station is pressed, irrespective of the sta-
te of the Day/Night function terminals.
Output B in monostable mode
(activation time from 01 s to 99 s)
Output B is activated for the programmed time after code
"B" has been correctly entered.
Outputs A and B in bistable mode
Outputs A and B are activated after their respective codes
"A" and "B" (2 or 5 digits) have been correctly entered, and
are deactivated after their recombination (only 5 digits).
The distinction between monostable or bistable operating
mode of the two outputs must be made in the code
69