Infiniton PAC-64WCH Manual De Usuario página 26

Tabla de contenido
Idiomas disponibles

Idiomas disponibles

5: Cover the air conditioning with a plastic bag. Put the air conditioning in a dry place, keep it
out of the reach of children, and take dust control measures.
6: Remove batteries of the remote control and keep them properly.
Note: ensure that the body is placed in a dry place and keep all machine components properly.
Do not repair or disassemble the air conditioning by yourself. Unqualified repair will lead to
failure of the warranty card, and may cause damage to users or their properties.
Problems
The
air
conditioning
does not work.
The cooling or
heating effect is
not good
Big Noise
The compressor
does not work.
The
remote
control does not
work.
Displays 'E1'.
Displays 'E2'
If problems not listed in the table occur or recommended solutions do not work, please contact the
professional service organization.
VII. Troubleshooting
Reasons
There is no electricity.
The overflow indicator displays "FL".
The ambient temperature is too low or
too high?
In
cooling
mode,
temperature is lower than the set
temperature; in heating mode, the
room temperature is higher than the
set temperature.
In
dehumidification
ambient temperature is low.
There is direct sunlight.
Doors or windows are open; there are
a lot of people; or in cooling mode,
there are other sources of heat.
The filter screen is dirty.
The air inlet or outlet is blocked.
The air conditioning is not placed on a
flat surface.
Overheat protection starts.
The distance between the machine and
the remote control is too far.
The remote control is not aligned with
the direction of the remote control
receiver.
Batteries are dead.
The pipe temperature sensor is
abnormal.
The room temperature sensor is
abnormal.
Page: 13/14
Solutions
Turn it on after connecting it to a socket with
electricity.
Discharge the water inside.
Recommend to use the machine in at the
temperature of 7-35 ℃ (44-95 ℉).
the
room
Change the set temperature.
The machine is placed in a room with an
mode,
the
ambient temperature of greater than 17 ℃
(62 ℉).
Pull the Curtain.
Close doors and windows, and add new air
conditioning.
Clean or replace the filter screen.
Clear obstructions.
Put the air conditioning on a flat and hard
place (to reduce noise).
Wait for 3 minutes until the temperature is
lowered, and then restart the machine.
Let the remote control get close to the air
conditioning, and make sure that the remote
control directly faces to the direction of the
remote control receiver.
Replace batteries.
Check the pipe temperature sensor and
related circuitry.
Check the room temperature sensor and
related circuitry.

Hide quick links:

Capítulos

Tabla de contenido
loading

Tabla de contenido