Technical instructions
DESCRIPTION
Specially suited for overflow pools, this regulation device keeps the water level
constant in the buffer tank. The NIVA system automatically controls:
-
The filling of the pool and the inhibition of the pump when the level is too low.
-
The manual overriding of the filtering pump if the level is too high. (Only for the
NIVA 5 model)
THE DISPLAY
The device displays the condition in which it is.
Level low
Filling
Pump inhibited
High level
Manual override
(only for the NIVA 5
model)
OPERATION
The system is switched on by the switch on the front panel of the box. The
ON light has to light up.
No water / Filling
As soon as the level of the buffer
tank
goes
down
"beginning of filling" level (only the
reference probe in the water), the
filling solenoid valve is activated and
the buffer tank is filled until the "end
of filling" level (3 probes in the water)
is reached again.
The system prevents the pump from
operating during this time and allows
it to operate again only when the
level goes above the probe S3.
CCEI
NIVA
below
the
S1
S2
S3
S4
M
(Only for the NIVA5 model)
End of filling
Beginning of filling
When the water level is low,
the filling light lights up.
v3.0
ON
page 4