Technical Data - Ingersoll Rand ENL 5 Vario Instrucciones De Instalación Y De Servicio

Grupo de repuesto
Tabla de contenido
Idiomas disponibles

Idiomas disponibles

EN
Further safety instructions:
For installation and operation, the national regulations
and safety codes in force must also be adhered to.
Do not use the ENL 5 Vario Service-Unit in hazardous
areas.
Regarding the inlet screw joints, excessive tightening
forces must be avoided. This applies in particular to
conical screw joints.
The ENL 5 Vario Service-Unit will only function when
voltage is applied.
Do not use the test button for permanent drainage.
Use genuine spare parts only. This is imperative to
ensure perfect functioning.
Additional advice:
The removed control unit has no IP degree of
protection.
During installation, use spanner flat at the feed pipe
(wrench size SW27) as a back rest.
The service unit must not be dismantled.
min./max. operating pressure
(see type plate)
min./max. temperature
(see type plate)
Condensate inflow
Condensate outflow
Condensate
Housing
Weight (empty)
4
2. SAFETy INSTRuCTIONS
malfunction during operation!
Through incorrect installation and poor maintenance,
malfunction may occur at the ENL 5 Vario Service-Unit.
Condensate which is not discharged may cause damage
to plants and in production processes.
measures:

3. TEChNICAL dATA

0,8...16 bar (12...20 psi) or 1,2...16 bar (17...20 psi)
+1...+60 °C (+4...+140 °F) or +1...+70 °C (+4...+158 °F)
NPT ½ (½") internal
max. screw-in depth 1,5 mm (½")
G ¼ (¼") Ø 8 ... 10 mm hose connector
oil-contaminated + oil-free
aluminium + plastic, glass fibre-reinforced
0,5 kg (1.1 lbs)
ingersollrandproducts.com
CAUTION
Condensate drainage which is reliable in performance
directly optimizes the compressed-air quality.
To prevent damage and breakdowns, it is imperative
to observe the following:
a.
Exact compliance with the specifications of use
and with the performance parameters of the
ENL 5 Vario Service-Unit , in connection with the
case of application (see "Proper use" section)
b.
Exact compliance with the installation- and
operation instructions in this manual
c.
Regular maintenance and control of the ENL 5
Vario Service-Unit in accordance with the instructions
in this operating manual
80448699
Tabla de contenido
loading

Este manual también es adecuado para:

38448239

Tabla de contenido