Hazardous pressure.
Can cause severe
injury or major
property damage
from tank blow up.
Release all pressure
and read instructions
before working on filter.
When to Clean the Filter
The filter module should normally be
cleaned when the pressure gauge reading
increases 10 PSI over the start-up pressure
(record the start-up pressure in a conve-
nient place).
In some pools, accessories such as foun-
tains or pool cleaners may be noticeably
affected by the normal decrease in flow as
the filter becomes dirty. If so, clean the fil-
ter more frequently (that is, at a pressure
increase of less than 10 PSI) in order to
maintain the required flow.
Recommended
Specialty Filter Cleaners
Filter Cleanse™,
Great Lakes Biochemical
BIOGUARD Strip Kwik™,
BIOGUARD KleenIt™, Softswim
Filter Cleaner,**
BIOLABS, Inc.
Filter Kleen™,
Haviland Products Co.
BAQUA CLEAN™, **
Zeneca, Inc.
** MUST be used when using any
PHMB based sanitizer.
MODULE CLEANING
PROCEDURE
Risk of chemical burns. Do not attempt to acid clean the filter or
module. If the filter requires acid cleaning, have a trained pool professional do
the job.
Follow all steps in the "Disassembly" section of this manual.
The filter module should be removed and cleaned when pressure rises more
than 10 psi (69 kPa) above startup pressure. See also "When to Clean the
Filter," at left.
NOTICE: Do not expose the filter module to sunlight for any extended period
of time.
NOTICE: When sanitizing your pool using PHMB (polyhexamethylene bi-
quanide based) cleaners, use only PHMB cleaners to clean the module. When
using PHMB sanitizers, the filter module MUST be cleaned more thoroughly
and frequently than for a pool using chlorine. Follow manufacturer's instruc-
tions carefully. Use of any other type of cleansers with PHMB pool sanitizers
will void the filter's warranty.
NOTICE: Avoid washing filter debris into the outlet port. Remove drain plug
and flush dirt from inside of tank before removing filter module.
1. With a hose equipped with a soft flow nozzle, wash as much dirt as possi-
ble off of the filter module while it is still inside the tank. Allow tank to
drain completely.
2. Make sure that the inside of the tank is clean. Lift out the module and
hose it down thoroughly. Spray the entire module surface. Allow module
to drain.
3. Inspect the module. If necessary, repeat the washing operation. If the
®
module is damaged, replace it.
NOTICE: If this cleaning method does not remove all deposits, see
"Special Cleaning Instructions" section in this manual.
4. Inspect and clean air bleed filter at top of module.
5. Follow all steps in the "Assembly" and "Initial Startup" sections of this
manual.
10