Installation
1. Ensure your product comes with the items indicated on pages 4–5; if not please
contact your branch.
2. Feed cables through backplate.
3. Use two screws to attach backplate to wall.
4. Use two screws to attach tamper plate to wall.
5. Connect cable to circuit board — see page 6.
6. Set output format — see page 7.
7. Configure reader — see page 10.
8. Snap reader to backplate and secure with final screw.
9. Apply power when all readers are installed.
Notes
•
If power is applied when the reader is not properly attached to the wall, a wall
tamper condition is generated.
•
Do not distort the back plate or tamper plate when mounting, e.g. to a back box,
or a spurious wall tamper / case tamper condition may be generated.
•
Mount readers >3' / 1m apart, e.g. on either side of the door. Mounting on metal
surfaces will reduce the reading range.
•
If the reader is being used to enter credential information to arm a system, the
reader must be located within 3' / 1m of the panel's main keypad or display.
•
For outside readers, use corrosion-resistant fixings and apply silicone sealant to
the backplate before fixing to the wall.
•
The supplied MOV (Metal Oxide Varistor, Anglia Components P/N B72207S250K101)
should be fitted across the power terminals of the lock to suppress back EMF. Any
suppression diodes fitted in the lock / lock circuit must be removed.
•
Output format and reader configuration can be changed without disconnecting the
power supply. The reader automatically restarts with the new configuration.
11