HOW TO INSTALL:
AT THE MACHINE (PERSON
Setup
Assemble machine.
Run hose to attic.
• Plug extension cord into AttiCat
110 V electrical outlet. Red light on machine will illuminate.
• Connect hose to machine.
• When ready for the flow of insulation, your assistant in the attic
will press the START button on the remote. This will illuminate the
green start button on machine; press it to start flow of insulation.
NOTE: AttiCat
machine will not operate unless START button is
®
pressed on the remote. Using the remote, your assistant may also
stop the machine while in the attic at any time.
• Using a knife, cut bag of insulation along cut line. Break package in
half; machine's feeder is specifically designed to accommodate a half-
bag of AttiCat
®
PINK Fiberglas
IN THE ATTIC (PERSON
Setup
Install eave baffles and
rigid barrier.
• Using a staple gun, install AttiCat
vertical framing to determine how much insulation you need to add.
Install one per every 300ft
/28m
2
• Install cardboard or metal baffling around heat-generating sources
such as can lights or flues/metal chimneys; keep cardboard and
insulation at least 3" from heat sources.
OWENS CORNING INSULATING SYSTEMS, LLC
ONE OWENS CORNING PARKWAY
TOLEDO, OHIO, USA 43659
1-800-GET-PINK
www.owenscorning.com
Pub. No. 10001747-B. Printed in U.S.A. June 2010. THE PINK PANTHER
&
©1964–2010
Metro-Goldwyn-Mayer
Reserved. The color PINK is a registered trademark of Owens Corning.
©2010 Owens Corning.
1)
#
Cut bags in half.
machine; connect to a standard
®
®
Blown-in Insulation.
2)
#
Install rulers.
rulers on joists, roof trusses, or
®
so that they are clearly visible.
2
®
Studios
Inc.
All
Rights
Use
Push half bag into
machine.
• Hold the half-bag by end flaps and insert cut end into machine.
Push half-bag completely into feeder until it stops. The built-in
Autocutter will cut plastic packaging thereby releasing insulation
into the machine. Packaging should be easy to remove.
• Remove packaging from machine. IMPORTANT: Packaging may clog
machine and should be removed once half-bag has released.
• Do NOT attempt to forcefully push or hand-feed loose insulation
down into machine.
• Add another half-bag of insulation once the machine feeder has
emptied and the agitator paddles can be seen through window.
Use
Push remote "START"
button when ready.
• Press the START button on the remote (person at machine will need
to press green start button on machine to begin flow of insulation).
To stop the flow of insulation at any time, press the STOP button on
the remote; this will stop the AttiCat
• Direct the hose toward the eaves, and begin by blowing insulation at
the point furthest from the attic opening. Insulation should flow out
of the hose and fall onto the surface 8 to 10 feet away.
• As each attic section is filled, move slowly backward toward the
attic opening. Repeat this process until attic is fully insulated.
• Ensure eave vents and heat-generating fixtures are not covered with
insulation.
• When you're close to the attic opening, use gloved hands to deflect
the insulation downward.
Remove packaging.
Blow insulation to
desired depth.
®
machine.
4
Please recycle packaging.
Recyclable LDPE
loading