SMART CHARGE IUoU Chargers
Front view 466095 (see figure 2)
The units can charge up to two supply batteries
No.
Description
1
Half power mode button
2
Connection for remote control
3
Control lamp
4
Switch field for the selection of the charging voltage
and time limitation (figure 8)
5
"+" (plus) terminal for the supply battery (1A Charge)
6
"+" (plus) terminal for the supply battery
7
"+" (plus) terminal for the supply battery
8
"-" (minus) terminal for the supply battery
5
Settings
5.1
Charging voltage and time
A switch field can select the charging voltage and the period for the main
charging phase.
Warning!
Make sure that switch 1 and 2 or switch 3 and 4 are never switched
on simultaneously while operating the charger. Please follow the
table below to ensure correct operation of the charger
5.1.1
Settings for the charging voltage
Refer to figure 8:
Voltage
Switch 1
Switch 2
13.8 V
OFF
OFF
14.4 V
ON
OFF
14.8 V
OFF
ON
5.1.2
Settings for the limitation of the period of the main charging
phase
Refer to figure 8:
13
Application range
Starter batteries, or using as a
12V power supply
Lead acid and gel batteries
AGM batteries
SMART CHARGE IUoU Chargers
Time limitation of
the main
Switch 3
Switch 4
charging
4 hrs.
OFF
8 hrs
ON
OFF
No timer function
OFF
OFF
5.2
Half power mode
If you push the button "Half Power Mode", the output power will reduce to half
the chargers amp rating and a green "Half ON" LED will light. The Half Power
LED is located on the bottom left corner of the front panel.
6
Mounting of Battery Charger
For the mounting of battery charger on wall or flat places, please refer to figures
10 & 11 regarding size of housing and location of mounting holes for your
installation.
7
Making Connections
Place the charger in a dry, cool, clean, and ventilated space.
o
Set the power switch to "0" (off) and pull out the main plug before
o
connection or disconnecting the direct current connection.
Connect the "-"(minus) battery pole with a connecting cable to
o
the"-"(minus) terminal at the IU0U automatic charger (see figure 1 & 2).
Connect the "+"(plus) battery pole with the connecting cable to the
o
"+"(plus) terminal at the IU0U automatic charger (see figure 1 & 2).
Lay all the cables from the batteries to the IU0U automatic charger (refer
o
to figure 6)
Fasten the cables ends with provided terminals (refer to figure 5).
o
For connection of starter batteries, please connect the terminal as our
o
drawing (see figure figure 7).
Ensure correct polarity of the battery and the battery charger, otherwise
o
the internal flat-pin terminal will trigger with the wrong polarity.
Note
Only use cables with the prescribed wire cross sections fro the connection of the
IU0U automatic charger to the battery.
Application range phase
ON
Lead acid or Starter batteries
AGM batteries or Gel batteries
Using as a 12V power supply
14