Battery Replacement; Troubleshooting - TFA 98.1040.01 Manual De Instrucciones

Tabla de contenido
Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 6
TFA_Anl. No. 98.1040.01_D_GB_ne
04.08.2016
Bedienungsanleitung
Instruction manual
RoHS
Fig. 1
A
Fig. 2
B
ON
C
OFF
REC
M.SET
RESET
D
E
F
Fig. 3
G
ON
OFF
H
REC
M.SET
RESET
15:25 Uhr
Seite 2
Radio controlled alarm clock
Thank you for choosing this instrument from TFA.
1. Before you use this product
• Please make sure you read the instruction manual carefully. This information will
help you to familiarise yourself with your new device, learn all of its functions and
parts, find out important details about its first use and how to operate it, and get
advice in the event of faults.
• Following and respecting the instructions in your manual will prevent damage to
your instrument and loss of your statutory rights arising from defects due to incor-
rect use.
• We shall not be liable for any damage occurring as a result of non following of
these instructions.
• Please take particular note of the safety advice!
• Please keep this instruction manual safe for future reference.
2. Delivery contents
• Radio controlled alarm clock
• Instruction manual
3. Field of operation and all of the benefits of your new instrument at a glance
• Radio-controlled clock with highest precision
• Analogue display with clock hands
• Display of seconds and date
• Alarm with snooze function
Kat. Nr. 98.1040.01
• Backlight
4. For your safety
• The product is exclusively intended for the field of application described above. It
should only be used as described within this instruction.
• Unauthorised repairs, modifications or changes to the product are prohibited.
Caution!
Risk of injury:
• Keep this instrument and the battery out of the reach of children.
• Batteries must not be thrown into a fire, short-circuited, taken apart or recharged.
1
Risk of explosion!
• Batteries contain harmful acids. Low batteries should be changed as soon as possi-
ble to prevent damage caused leaking.
• Wear chemical-resistant protective gloves and glasses when handling leaking bat-
teries.
Important information on product safety!
• Do not place the unit near extreme temperatures, vibrations or shocks.
• Protect it from moisture.
5. Elements
LCD display (Fig. 1)
A: Time signal symbol
Symbol Daylight Saving Time
Display of seconds and date
Buttons (Fig. 2)
Kat. Nr. 98.1040.01
B: Dial for the alarm time
C: Switch ON/OFF
D: REC button
E: M.SET button
F: RESET button
Housing (Fig. 3)
G: SNOOZE/LIGHT button
H: Battery compartment
6. Getting started
• Open the battery compartment and insert a new battery (1,5 V AA), ensure battery
polarity is correct.
• A brief beep tone will sound and all segments will be shown for few seconds.
• The unit is ready for use.
• The clock hands move to 12 o'clock and the clock is trying to receive the radio signal
for 3 - 12 minutes.
• 00 appears on the display and the radio signal symbol flashes.
• When the time code is received, the radio-controlled time will be shown and the
seconds appear on the display.
• The radio signal symbol appears.
• Twelve times a day receives the clock the radio signal.
• Manual initialization can be helpful. Press and hold REC button for 3 seconds. The
clock hands move to 12 o'clock and the clock is trying to receive radio signal again.
• If the clock cannot detect the DCF-signal (for example due to disturbances, transmit-
ting distance, etc.), the time can be set manually. The DCF symbol disappears and
the clock will then work as a normal quartz clock. (see: Manual setting of the time).
6.1 Radio-controlled time reception
Kat. Nr. 98.1040.01
The time base for the radio-controlled time is a caesium atomic clock operated by the
Physikalisch Technische Bundesanstalt Braunschweig. It has a time deviation of less
than one second in one million years. The time is coded and transmitted from Main-
flingen near Frankfurt via frequency signal DCF-77 (77.5 kHz) and has a transmitting
range of approximately 1,500 km. Changeover from summer time or winter time is
automatic. In Daylight Saving Time "S" is shown on the LCD. The quality of the recep-
tion depends mainly on the geographic location. Normally there should be no recep-
tion problems within a 1,500 km radius around Frankfurt.
Please take note of the following:
• The recommended distance to any interfering sources like computer monitors or TV
sets is at least 1.5 - 2 metres.
• Inside ferro-concrete rooms (basements, superstructures), the received signal is nat-
urally weakened. In extreme cases, please place the unit close to a window to
improve the reception.
• During nighttime, the atmospheric interference is usually less severe and reception
is possible in most cases. A single daily reception is adequate to keep the accuracy
deviation below 1 second.
7. Operation
• The instrument will automatically quit the setting mode if no button is pressed
within 8 seconds.
7.1 Manual setting of the time
• Press and hold M.SET button for three seconds.
• The radio signal symbol disappears and the indication of seconds stops.
• Hold the button until the desired time is indicated.
• Press the button briefly the clock hands move minute by minute.
• The manually set time will be overwritten by the DCF time when the signal is
Kat. Nr. 98.1040.01
received successfully.
Radio controlled alarm clock
7.2 Setting of the alarm time
• Turn the dial for the alarm time and set your respective alarm time (in direction of
the arrow).
• To activate the alarm function, move the switch ON/OFF upwards (ON).
• When the alarm time is reached, the alarm will ring for 2 minutes.
• If it is not stopped, the alarm will automatically turn off after 2 minutes and will be
reactivated at the same time.
• When the alarm rings, press SNOOZE/LIGHT button and the snooze function is acti-
vated. The backlight turns on for a short time.
• The alarm will be interrupted for 5 minutes.
• The snooze function can be activated up to seven times.
• Move the ON/OFF switch downwards (OFF), the alarm function is deactivated.
7.3 Display of seconds and date
• Once the reception of the DCF time is successful press M.SET button to toggle
between the display of seconds and date:
• Display of date: Press the REC button to toggle between M/D month/day
sequence (American version) or D/M day/month (European version).
Attention: If there is no DCF reception possible only the seconds appear on the display.
7.4 Backlight
• Press SNOOZE/LIGHT button. The backlight will come on for 5 seconds.
8. Care and maintenance
• Clean it with a soft damp cloth. Do not use solvents or scouring agents.
• Remove the battery if the device will not be used for an extended period of time.
• Keep the instrument in a dry place.

8.1 Battery replacement

• Replace the battery when the functions of the instrument become weak.
• Open the battery compartment and insert a new battery 1,5 V AA.
• Making sure the polarity is correct.
• Close the battery compartment again.

9. Troubleshooting

Problems
Solutions
➜ Ensure battery polarity is correct
No indication / no clock
➜ Change the battery
hands movement
➜ Press and hold REC button and start a new reception
No DCF reception
➜ Choose another place for the device
➜ Check if there is any source of interference
➜ Wait for attempted reception during the night
➜ Manual time setting
➜ Restart the device as per the manual or use a pin to press
the RESET button
➜ Change the battery
Incorrect indication
If your device fails to work despite these measures contact the supplier from whom you
purchased it.
10. Waste disposal
This product has been manufactured using high-grade materials and components
which can be recycled and reused.
Never dispose of empty batteries and rechargeable batteries in household
waste.
As a consumer, you are legally required to take them to your retail store or
to appropriate collection sites depending on national or local regulations in
order to protect the environment.
The symbols for the heavy metals contained are:
Cd=cadmium, Hg=mercury, Pb=lead
This instrument is labelled in accordance with the EU Waste Electrical and
Electronic Equipment Directive (WEEE).
Please do not dispose of this instrument in household waste. The user is
obligated to take end-of-life devices to a designated collection point for
the disposal of electrical and electronic equipment, in order to ensure
environmentally-compatible disposal.
11. Specifications
Power consumption:
Battery 1 x 1,5 V AA (not included)
Housing dimension:
96 x 55 x 119 mm
Weight:
140 g (only instrument)
No part of this manual may be reproduced without written consent of TFA Dostmann. The technical
data are correct at the time of going to print and may change without prior notice.
The latest technical data and information about your product can be found by entering your product
number on our homepage.
EU declaration of conformity
Hereby, TFA Dostmann declares that the radio equipment type 98.1040.01 is in compliance with
Directive 2014/53/EU.
The full text of the EU declaration of conformity is available at the following internet address:
www.tfa-dostmann.de
TFA Dostmann GmbH & Co.KG, Zum Ottersberg 12, D-97877 Wertheim, Germany
08/16
Tabla de contenido
loading

Tabla de contenido