Replacing Brushes - Aqua Products EP37 Serie Manual Del Usuario

Tabla de contenido
Idiomas disponibles

Idiomas disponibles

12
Figure 18. Lay Cable in the Sun

Replacing Brushes

The cleaner is fitted with a brush in front. There
are ''wear'' indicators on the brush (Figure 19). To
maintain cleaner performance at its best, replace
the brush as soon as the wear indicator has been
reached. Aqua Products recommends that you
replace the brushes every two (2) years.
Figure 19. Worn Brush Indicator
To maintain cleaner performance at its best you
need to replace the brush as soon as one of the
wear indicators is reached (even if the blade wear
is not even). It is recommended that you replace
the brush when the rubber is worn down to the
top of the wear indicator (or every two years,
whichever comes first).
To replace a worn brush:
1.
Separate the edges of the brush, undo
the tabs, and remove the worn brush.
2.
Position the new brush underneath the
roller with the spikes facing downwards
(Figure 20).
Figure 20. Position the New Brush on Roller
3.
raised groove becomes
partially flattened,
indicating excessive
wear
Figure 21. Pull Tabs Through Each Slot
4.
Figure 22. Cut Tabs
Thread each tab into the slot provided
and gently feed it through until the heel
comes out at the other side of the slot
(Figure 21).
4
Use scissors to cut the tabs so they are no
higher than the spikes (Figure 22).