recommended remedies below.
Trouble
Blower fails to operate
Blower operates intermittently
Blower vibrates abnormally
Impeller will not turn freely
Rated voltage
Rated power
Unloaded speed
Airflow
Air velocity
Weight
Protection class
Environmental protection
• Waste electrical products should not be disposed of with household waste.
• Please recycle where facilities exist.
• Check with your local authority or retailer for recycling advice.
6
MAINTENANCE
3. Use a soft brush to remove debris from the air vents.
4. Inspect the tool carefully. If the tool is damaged in any
6. Store in a cool, dry place and out of reach of children.
TROUBLESHOOTING
Cause
1. No power
2. Faulty wall outlet
3. Extension cord damaged
4. Circuit breaker shut off or faulty
1. Extension cord damaged
2. Loose internal connection
3. Internal wiring defective
1. Mechanical failure
1. Debris in air intake area
2. Mechanical failure
TECHNICAL DATA
cloth. Never clean the tool with water, cleaning fluids,
or solvents.
way, contact an authorized service center. Never use a
damaged tool.
Remedy
1. Check power
2. Use another outlet
3. Check cord, replace
4. Reset or replace circuit breaker
1. Check cord, replace
2. Call an authorized service center
3. Call an authorized service center
1. Call an authorized service center
1. Remove debris
2. Call an authorized service center
WE7B
120V~60Hz
900 W (7.5 A)
14,700 – 15,700 min
3
6.8 m
/min (240 cfm)
257.5 kph (160 mph)
2.75 kg (6.1 lb)
-1
/ II