Preparation; Preparing The Installation Site; Installation Site Requirements Of The Indoor Unit; Installation - Daikin FTXP50M2V1B Manual De Instalación

Ocultar thumbs Ver también para FTXP50M2V1B:
Tabla de contenido
4

Preparation

4.1

Preparing the installation site

WARNING
The appliance shall be stored in a room without
continuously operating ignition sources (example: open
flames, an operating gas appliance or an operating electric
heater).
4.1.1
Installation site requirements of the
indoor unit
INFORMATION
The sound pressure level is less than 70 dBA.
▪ Air flow. Make sure nothing blocks the air flow.
▪ Drainage. Make sure condensation water can be evacuated
properly.
▪ Wall insulation. When conditions in the wall exceed 30°C and a
relative humidity of 80%, or when fresh air is inducted into the
wall, then additional insulation is required (minimum 10  mm
thickness, polyethylene foam).
▪ Wall strength. Check whether the wall or the floor is strong
enough to support the weight of the unit. If there is a risk, reinforce
the wall or the floor before installing the unit.
▪ Spacing. Install the unit at least 1.8 m from the floor and keep the
following requirements in mind for distances from the walls and
the ceiling:
≥50
5

Installation

5.1

Opening the indoor unit

5.1.1

To remove the front panel

1 Hold the front panel by the panel tabs on both sides and open
it.
a
Panel tabs
2 Remove the front panel by sliding it to the left or the right and
pulling it toward you.
Result: The front panel shaft on 1 side will be disconnected.
3 Disconnect the front panel shaft on the other side in the same
manner.
FTXP50~71M2V1B + FTXF20~71A2V1B
Daikin room air conditioner
3P512025-7H – 2018.09
a
5.1.2
1 Attach the front panel. Align the shafts with the slots and push
2 Close the front panel slowly; press at both sides and at the
5.1.3
1 Remove the front panel to remove the air filter.
2 Remove 2 screws (class 20~35) or 3 screws (class 50~71) from
3 Push down the 3 upper hooks marked with a symbol with 3
≥50
a
(mm)
4 We recommend opening the flap before removing the front
5 Place both hands under the centre of the front grille, push it up
a
5.1.4
1 Install the front grille and firmly engage the 3 upper hooks.
2 Install 2 screws (class 20~35) or 3 screws (class 50~71) back
3 Install the air filter and then mount the front panel.
a
Front panel shaft

To re-install the front panel

them all the way in.
centre.

To remove the front grille

CAUTION
Wear adequate personal protective equipment (protective
gloves, safety glasses,...) when installing, maintaining or
servicing the system.
the front grille.
circles.
b
a
Upper hook
b
Symbol with 3 circles
grille.
and then toward you.

To re-install the front grille

on the front grille.
4 Preparation
a
Installation manual
7
Tabla de contenido
loading

Tabla de contenido