INSTALLATION
• Install filter after water meter or pressure tank.
• Only Teflon
tape is recommended for fitting connections.
®
• Instructions are for installing 1˝ compression fittings
(separate fittings required for other sizes and non-copper pipe).
1
A
Turn off water supply (A) and open nearest
faucet to drain pipes before installation.
Apply about 6˝ of Teflon
direction to pipe threads of each adapter.
IMPORTANT: When choosing location allow
1-1/2˝– 2˝ clearance below housing to allow
for filter changes.
3
Assemble all fittings. Start adapters (not
included) into filter head by hand. Use a wrench
to tighten firmly.
DO NOT OVER-TIGHTEN.
B
tape (B) in clockwise
®
2
If using optional BR-C mounting bracket, start by
making sure the arrows facing you on the system
are consistent with the direction of your water
flow. If necessary, remove filter life indicator
holder if on the back side of the unit, and move
it to the front. Align the holes of the bracket with
the holes on the back of the filter head. Insert four
mounting screws through the bracket and into the
filter head until tight. Otherwise skip to step 3.
5