1. Installation and safety (see also page 1 for safety information)
• Connection or installation may only be carried out by qualified electricians!
• Always switch on the circuit in which the installation is being carried out during all work
the main fuse completely! Otherwise there is a DANGER TO LIFE !!
• For optimal functionality, mount the motion detector at right angles to the direction of
travel of the area that is to be scanned. If people move directly towards the motion
detector, the function is only possible to a limited extent!
• Insert the stripped wires of the input and output cables into the terminal
on the motion detector and screw it tight! Check that the wires are firmly seated.
• Do not install near sources of heat or cold
1. First, carefully remove the
front cover
eg with a phase tester.
Important instructions:
suitable for e.g. two-way circuits, cross-connections, push-button circuits,
The sensor is NOT
impulse relays or parallel circuits. The sensor has a highly sensitive thyristor output and is NOT
reverse current proof. The sensor is designed to switch one or more consumers (e.g. lamps) in
a circuit on or off from one installation location. The sensor replaced an ON / OFF switch.
Direction of movement always
parallel to the sensor
Range max. 9m
Settings and function test
Now set the controller for LUX to the "right stop"! Set the time setting to "left stop". Attach the
cover plate and turn the power back on. Now switch the function switch to "ON", then the sensor
switches and the lamp will light up. Now switch the function switch to "OFF", the lamp goes out.
Then set it to "PIR". The motion sensor is now active and reacts to people in the detection
area. The sensor switches off again after approx. 7 seconds. Finally, adjust the switch-on time
(TIME) and the twilight threshold (LUX) as required.
Electricity flows, the lamp lights up.
• Position "ON"
no current flows, the device is deactivated, the lamp does not light up.
• Position "OFF"
Motion detector is active and reacts according to the default settings
• Position "PIR"
Reproduction only with permission from ChiliTec GmbH, teaching
operation manual
- Product data sheet page 2/3 -
2. Connect L (phase) and A
(phase output to lamp)
at - DANGER: The sensor
does not require a neutral conductor
PIR sensor
Acquisition approx. 160 °
EAR (WEEE): DE25841852
LUCID Packaging Act: DE5562476395648
GRS (UBA register) No .: 21003466
Status: 01/2020 - Ver. 1.02
3. Insert the sensor into the
flush-mounted box and
attach the sensor
lamp
Settings
9m
The sensor must not be without a consumer
and not with a defective consumer
operate.