Note:
If the 7" (17.8 cm) side lite bracket is used,
use the 11" (27.9 cm) threshold filler. If the
13" (33 cm) side lite bracket is used, use
the 17" (43.2 cm) threshold filler.
Apply silicone sealant to channel
located under bracket.
Position channel
towards outside (dry
side) of shower.
2. Install the Bottom Side Lite Bracket
Insert the appropriate threshold filler into the side lite bracket in the groove located on top of the
threshold. If the 7" (17.8 cm) side lite bracket is used, use the 11" (27.9 cm) threshold filler. If the 13"
(33 cm) side lite bracket is used, use the 17" (43.2 cm) threshold filler. Position the filler against the
wall on the same side that the side lite panel will be installed.
Identify the bottom side lite bracket. When placed in the correct position on the threshold, the
bracket weep slots will be towards the inside (wet side) of the shower, and the channel will be
towards the outside (dry side) of the shower (weep slots and channel will be on opposite edges for
the top side lite bracket).
Place the side lite bracket on the threshold, flush against the wall and flush against the threshold
filler.
NOTE: Be careful not to drill through the receptor ledge.
Mark the hole location through the bracket hole and remove the bracket. Using the supplied 7/64"
drill bit, drill a hole through threshold at the location marked and clean out the filings.
Apply silicone sealant to the channel on the bottom of the bracket and place on the threshold at its
previous location. Secure the bracket to the threshold using #6-20 x 3/8" screw.
Kohler Co.
Threshold Filler
Threshold
Position weep slots towards
inside (wet side) of shower.
5
#6-20 x 3/8" Screw
Bottom Side
Lite Bracket
Bracket Hole
Weep
Slot
Inside of Shower
1011451-2-F