Wiring
Administrator programming
Use point fingers as Administrator and Installer. You can use the other fingers as access fingers.
Administrator finger is enrolled at the end of the system installation. Initial enrolment of the Admin finger is described in installer
manual.
Adding admin fingerprint
1. Set the DIPSWITCH n.º 2 in position ON.
2. Reset the power of the device.
3. Wait for 1 long + multiple short beeps.
4. Set the DIPSWITCH n.º 2 in position OFF. (short beeps will stop)
5. Wait for about 15 seconds for the LED to blink in ORANGE
6. Swipe the MASTER finger min. 6 times. (until OK beep)
Warning: with this procedure also deletes all users and installer finger .
ORANGE
LEFT
RIGHT
RED
12_24 ac_dc
BLACK
PINK
A
RS485
VIOLET
B
BLUE
Tamper NC
GREEN
EXIT Button
GREY
NC
YELLOW
COM
WHITE
NO
ON
No.2
1
2
12/24V AC/DC
ON
No.2
1
2
x 6